[TechAssist] Orion TVCR1921 fixed

  • From: "J Silverman" <greentron@xxxxxxxxxxxxxxxx>
  • To: <Techassist@xxxxxxxxxxxxx>
  • Date: Sat, 30 Mar 2002 14:40:59 -0500

Same as VT1921A.
Symptom - Dead after storm
Fix - D512 (21DQ09 3 amp 90 volt schottky) and ICP502 (2 amp fuse).
Note - Second time we have seen this combination on this model.
Jerry Silverman
Greentron Inc
4 Newland Ave
Greenville SC 29609
864 232 3889
Fax 271 2080
mailto:greentron@xxxxxxx


------------------------------------------
Make your TechAssist database better!  
Submit Repair Tips here: http://www.tech-assist.org/secure/tip/
------------------------------------------
To UNSUBSCRIBE your email address, click here:
mailto:techassist-request@xxxxxxxxxxxxx?subject=unsubscribe
Or send a BLANK email with unsubscribe in the
SUBJECT field to the address above.

Other related posts:

  • » [TechAssist] Orion TVCR1921 fixed