Just the generac procedure for most mitsi's: ESR all lytics, look for stains on the board, repl. leaking caps. usually any type of smear with these involve SMD lytics as well as thru the board types. Phil Bader Ed Gaidies wrote: >Anyone have a quick fix for Smeared OSD for these 20" sets. > >I repaired this set with a Shut Down problem...and not going to spend >much time on this other problem..unless someone has run into it previously. > >Thanks.. >-Ed- > > > -- Philip Bader Jan Phyl TV Inc. (estab. 1976) 3420 Recker Hwy. Winter Haven, Fl. 33880 Fax (863) 299-8821 email: tjanphyl@xxxxxxxxxxxxxxx -- No virus found in this outgoing message. Checked by AVG Anti-Virus. Version: 7.0.300 / Virus Database: 266.5.5 - Release Date: 3/1/2005 ----------------------------------------------------------------------------- This Email List is viewable to the Public. Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/