Above unit came in with HOT Q502 shorted, F104 open and R432 burned. Replaced these components and IC410 and Q400 to be on the safe side. Checked over and resoldered the usual connections in and around T505, esr'd the caps and replaced C431 as questionable. Set fires up on iso-transformer at 90v but R432 off pin 2 of IC410 immediately gets hot and would burn if I'd let it. Checked out the diodes beyond that circuit and tested Q420, Q510 and Q403 but not finding the problem. Anyone had this particular problem with this chassis before. Could really use some help. Bill William H. Rayburn, CET NESDA Member Premium Technologies PO Box 442 Long Beach, Wa. 98631 (360) 642-4993 ----------------------------------------------------------------------------- Jokes, complaints, off topics, general chat. Everything other than repair help problems can be found at this new list. No archives and posts will not be found on Google or any other engine!To remove or join, email chat-request@xxxxxxxxxxxxxxx with remove or join as the subject. Send to the list at chat@xxxxxxxxxxxxxxx once subscribed. ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/