[tarantool-patches] Re: [PATCH 3/3] Syslog destination test unix socket

  • From: Vladimir Davydov <vdavydov.dev@xxxxxxxxx>
  • To: Olga Arkhangelskaia <arkholga@xxxxxxxxxxxxx>
  • Date: Fri, 13 Jul 2018 16:34:25 +0300

On Fri, Jul 13, 2018 at 01:29:38PM +0300, Olga Arkhangelskaia wrote:

Adds syslog destination unix test in app-tap.
Test redirects logs to newly created unix socket and sets appropriate
log level. If log receives the same level - test passes.
Usage: test-run.py syslog

Signed-off-by: Olga Arkhangelskaia <arkholga@xxxxxxxxxxxxx>
---
 test/app-tap/syslog_socket.test.lua | 33 +++++++++++++++++++++++++++++++++
 1 file changed, 33 insertions(+)
 create mode 100755 test/app-tap/syslog_socket.test.lua

diff --git a/test/app-tap/syslog_socket.test.lua 
b/test/app-tap/syslog_socket.test.lua
new file mode 100755
index 000000000..bc65ffd5e
--- /dev/null
+++ b/test/app-tap/syslog_socket.test.lua
@@ -0,0 +1,33 @@
+#!/usr/bin/env tarantool
+
+local tap = require('tap')
+local socket = require('socket')
+local os = require('os')
+local test = tap.test("syslog_unix")
+
+test:plan(1)
+local function start_server(test, sock_addr)
+    test:diag("Create unix socket")
+    local destination = 'unix:'.. sock_addr
+    local unix_socket = socket('AF_UNIX', 'SOCK_DGRAM',0)

You don't need datagrams here. Please use SOCK_STREAM.

+    unix_socket:bind('unix/', sock_addr)
+    socket.tcp_connect('unix', sock_addr)
+    unix_socket:listen()
+    return unix_socket, destination
+end
+
+local function find_log_level (test, socket, destination)
+     local buf
+     local opt = 'syslog:server='..destination..',identity=tarantool'
+     box.cfg{log = opt, log_level = 7}
+     buf = socket:read(300)
+     test:ok(buf:match('log level 7'))
+end
+
+path = '/tmp/syslog_test.sock'

Better create the socket in the current directory to avoid conflicts.
For example, see

https://github.com/tarantool/tarantool/blob/fbf8be12dbb041026fc7c81018ac5f02a9fc9d18/test/app-tap/console.test.lua#L14

+sock, dst = start_server(test, path)
+
+test:test('syslog_unix',find_log_level(test, sock, dst))
+sock:close()
+os.remove(path)
+os.exit(test:check() == true)

Please also check that an invalid address is handled properly so as to
cover error paths. The same's fair for the previous test case too.