[SI-LIST] noncausal ripples in impulse response

  • From: Tramp <farhilltramper@xxxxxxxxx>
  • To: si-list <si-list@xxxxxxxxxxxxx>
  • Date: Thu, 11 Jun 2020 12:43:25 +0100

Hi experts,
When obtaining the impulse response using ifft, often the generated ir
(impulse response) shows a bit of ripple&noise before t=0. I did some
experiments and here is the observation:

1. Increasing fmax, which is the max freq for the IL extrapolation, doesnt
help reduce the ripple.
2. Changing delta-f shows no avail as well.
3. Although the causality of the sparam is already good enough, still I
tried composing a 'causal' sparam by replacing the imag part of the sparam
w/ the Hilbert transform of the real part. Unfortunately, the thereafter
produced ir is a complete mess. What went wrong here?

I read from some literatures where the authors said they simply zero-out
all the ripples before t=0. Is this a recommended approach? Are there
better solutions to obtain a genuine ir?

Best Regards,

Tramp


------------------------------------------------------------------