[SI-LIST] ground plane resonance of stripline

  • From: "Juyoung Lee" <dmarc-noreply-outsider@xxxxxxxxxxxxx> (Redacted sender "juylee2000" for DMARC)
  • To: "si-list@xxxxxxxxxxxxx" <si-list@xxxxxxxxxxxxx>
  • Date: Wed, 12 Jul 2017 21:04:24 +0000 (UTC)

Hi,
I am trying to build about 8 inch long stripline test structure.If there are no 
ground vias stitched along the stripline except at end points, I can imagine 
there would be resonances between the ground planes theoretically. If it 
happens, would it appear as resonance dips in the insertion loss curve? 
Or is it a myth that wouldn't happen in practice? When I tried simulations with 
HFSS for 2 inch long stripline, I didn't see resonance in S21. 

Regards,Juyoung Lee


------------------------------------------------------------------