Hi All,

I have posted the latest article on my website at http://emcesd.com:
Cable Effects Pt 3: Capacitive Pickup by Cables in a System

Last month the Technical Tidbit on http://emcesd.com explored inductive
coupling to cables. The article for March discusses capacitive coupling
to cables in a system and how to distinguish it from inductive coupling
by measurement technique. Also shown is how little coupling capacitance
is needed to keep you from shipping a system.

Enjoy! (I enjoy writing these articles and hope most of you enjoy
reading them!)