Dear  All ,
 
I happened to look into the Step Down Converters from MonothilicPower.
The following is the statement made in the webpage:
 
MPS presents the MP2309 and MP2307 23V synchronous step-down regulators.
With an output current rating of 1A and 3A respectively, the MP2309 and
MP2307 are pin compatible with the 2A MP2305, forming a power management
solution that can easily scale from 1A to 3A without circuit board
re-design. 
 
http://www.monolithicpower.com/fpga_xilinx_spartan.htm 
 
Could  anyone  please explain how come this is feasible.
 
 Following are the general rules for a step Down converter:
 
1) Since the input capacitor (C1) absorbs the input switching current it
requires an adequate ripple current rating.
2) The worst-case condition occurs at VIN = 2VOUT,where IC1 = ILOAD/2.
3) Inductor should be chosen that it will not saturate under the maximum
inductor peak current. The peak inductor current hence is dependent on
the Load Current.
 
Hence how is that if  we  want to change to a different load
requirement, only a Monolithic power solution Chip change is enough. How
come the external components remain with the same rating for different
loads.
 
Please can anyone explain this . It will be of great learning to us
here.
 
Thanks
Regards
Vivek.


DISCLAIMER:
-----------------------------------------------------------------------------------------------------------------------

The contents of this e-mail and any attachment(s) are confidential and intended 
for the named recipient(s) only.
It shall not attach any liability on the originator or HCL or its affiliates. 
Any views or opinions presented in 
this email are solely those of the author and may not necessarily reflect the 
opinions of HCL or its affiliates.
Any form of reproduction, dissemination, copying, disclosure, modification, 
distribution and / or publication of 
this message without the prior written consent of the author of this e-mail is 
strictly prohibited. If you have 
received this email in error please delete it and notify the sender 
immediately. Before opening any mail and 
attachments please check them for viruses and defect.

-----------------------------------------------------------------------------------------------------------------------

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts: