What can close the loop in your thoughts are the considerations that S
parameters are
steady-state frequency-domain linearized descriptors based on a chosen
reference
impedance. Moreover, we usually describe only the passive channel by S
parameters.
In the actual application, you have to consider also the terminations
instead of the
chosen normalization impedance, so you need to add the actual source
impedance
of the driver and the actual load impedance of receiver. The silicon
impedance tends
to be high compared to the typical 50-ohm reference impedance and
therefore by the
time you consider these impedances, what matters much more is voltage
(though
neither the reactive nor the dissipative power is going to be absolutely
zero in a real case).
Regards,
Istvan Novak
Samtec
On 12/8/2019 10:36 AM, Tramp wrote:
Hi experts,------------------------------------------------------------------
We all know sparam is power based. But when it comes to the RX sampler, it
seems to be voltage based to me. This is bcs that the slicer doesnt care if
the voltage it is sampling is inphase w/ time, or out of phase since it can
shift its time base to locate the peaks of incoming voltage. In other
words, what is cared for is the apparent power rather than the effective
power.
is my understanding correct?
Best Regards,
Tramp
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field
or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list
For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field
List forum is accessible at:
http://tech.groups.yahoo.com/group/si-list
List archives are viewable at:
//www.freelists.org/archives/si-list
Old (prior to June 6, 2001) list archives are viewable at:
http://www.qsl.net/wb6tpu