[SI-LIST] Passing UTP Ethernet with EN300113?

  • From: VK3YNG Listmail <listmail@xxxxxxxxxxxxxx>
  • To: "si-list (si-list@xxxxxxxxxxxxx)" <si-list@xxxxxxxxxxxxx>
  • Date: Mon, 5 Dec 2016 20:36:35 +1100

Hi all,
      I would like to hear from anyone who has managed to get a **clear** pass 
for 100Mbps Ethernet when tested to ETSI EN 300113 (V2.1.0 or equivalent) using 
UTP cable.

Over multiple products I have always had a hard time meeting it without going 
to STP cable and the emissions always seem to be very cable dependant. One 
cable can give a completely different spectra than another over an 
approximately 36-110MHz range.

PLEASE, and I must insist this, I only want to hear from someone who has 
**actually achieved** this and therefore possibly what you used for Phy and 
magnetics or some other trick. I am not particularly interested in opinions and 
suggestions from people that have only achieved basic CISPR 22 passes as this 
standard (with its -57dBm substitution equivalent) seems to be a tough nut to 
crack!

Regards,
Bryan Ackerly


------------------------------------------------------------------