The 20 warnings about Rising and Falling Endpoints not within 2% of the = value given by the V/I curves, also happens occasionally. This warning can happen if the voltage/time waveforms are truncated and = don't last long enough to approach steady-state. Or it can also happen = if the final value in the V/T tables (suggesting steady-state), does not = agree with what you would expect to get, if you take the intersection of = the V/I curves with the load-line of the test load (Rfixture, Vfixture). = Either would suggest problems in the vendor's IBIS model. Andy ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu