Sorry. Just corrected the subject. 2009/9/20 Shawn Zheng <shawn.h.zheng@xxxxxxxxx> > Just found that FEXT doesnt necessarily increases as spacing between two > single ended traces increases. > FEXT coefficient is proportional to Cm/L-Lm/L. As traces are separated > further, both mutual indutance and capacitance decrease. So I think it makes > sense that total FEXT may not necessarily become less. > For 8mil wide microstrip line with 4mil dielectric thickness, I sweep the > distance between two traces from 10mil to 29mil. By observing s parameter, > > 10mil>11mil>12mil>13mil>14mil>15mil>16mil>17mil>18mil>19mil>20mil>22mil>21mil>25mil>24mil>23mil>26mil>27mil>29mil>28mil. > 25mil spacing has more xtalk than 24mil and 23mil spacings. > Does it seem correct to you? > > Shawn > > > ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list or at our remote archives: http://groups.yahoo.com/group/si-list/messages Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu