Hi Techies, I am using an SOIC with two DDR3 controllers inside for a mobile base station application. The configuration for each controller is 32 Bit+4 Bit ECC (128MB - 4 devices for data and One for ECC). So there will be total of 10 on board DDR3 ICs. I have choose TPS51200 for the VTT regulator and my question is Can I use the same regulator for both the controller VTT power? Ie I am planning to use a single TPS51200 regulator (0.75V VTT) for all 10 devices (5 each on the controller). Can anybody suggests is there any issues by connecting like this. I searched for some application note but I could not find any details. The calculation is as below TPS51200- 3A Source/ Sink regulator Current/ terminal = 0.75V/36.5= 20mA (Termination R = 36.5 Ohm) Total no of termination lines = 26 Lines Therefore the total current = 26 * 20 = 520mA For two DDR3 controller the Total current requirement is = 520*2= 1040mA Since regulator is capable of sourcing 3A can I use same regulator for both the case? Please give me your suggestions. Thanks, Jose ------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu