Hi Mohamad, I tried to get different results with the same frequency range settings as you had. But I get the same results regardless of the simulation options settings. I'm running Siwave version 4.0.1 BR Peter >-----Original Message----- >From: si-list-bounce@xxxxxxxxxxxxx >[mailto:si-list-bounce@xxxxxxxxxxxxx] On Behalf Of ext Havermann, Gert >Sent: 8. december 2009 10:28 >To: Mohamad Haghtalab; si-list@xxxxxxxxxxxxx >Subject: [SI-LIST] AW: changing Frequency Response! > >Hi Mohammad, > >I've never used SIwave, but here are some Ideas what might >have happend. >Please check that your second simulation uses the same >frequency points you had in the first simulation. Quite often >the interpolation between the points can make things look >different. You should also check if the impedance of the >source, line and termination is exactly the same. Any mismatch >will result in reflections and standing waves. Take a look at >the S-Parameters of both simulations, they should be equal up >to 5GHz. If you see equally spaced ripples in S11, then there >are impedance discontinuities. > >For software related problems please see the ANSOFT Engineers, >they will be happy to help . > >BR >Gert > > >--------------------------------------------------------------- >----------- >Absender ist HARTING Electronics GmbH & Co. KG; Sitz der >Gesellschaft: Espelkamp; Registergericht: Bad Oeynhausen; >Register-Nr.: HRA 5596; persönlich haftende Gesellschafterin: >HARTING Electronics Management GmbH; Sitz der >Komplementär-GmbH: Espelkamp; Registergericht der >Komplementär-GmbH: Bad Oeynhausen; Register-Nr. der >Komplementär-GmbH: HRB 8808; Geschäftsführer: Torsten Ratzmann >-----Ursprüngliche Nachricht----- > >Von: si-list-bounce@xxxxxxxxxxxxx >[mailto:si-list-bounce@xxxxxxxxxxxxx] Im Auftrag von Mohamad Haghtalab >Gesendet: Montag, 7. Dezember 2009 13:06 >An: si-list@xxxxxxxxxxxxx >Betreff: [SI-LIST] changing Frequency Response! > >Hi all > >I've faced a bad challenge in simulating frequency response of >Xtalk between two nets in my PCB, my simulating setup is as >follows:(I did it in SIWave(Ansoft)) > >a voltage source is attached to a terminated transmission line >with internal impedance equal to characteristic impedance of >the line,(the line is also terminated in appropriate >impedance),I've placed voltage probes in different locations >that measure the induced voltage,the frequency of voltage >source first sweeps from 1meg to five giga hertz with 200 >points in frequency response,then i simulated with frequency >ranged from 1meg to ten giga hertz,the responses are very >different between these two simulations in common points >(between 1 meg to five giga hertz)!,why? > >Thanks for Help > > >------------------------------------------------------------------ >To unsubscribe from si-list: >si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > >or to administer your membership from a web page, go to: >//www.freelists.org/webpage/si-list > >For help: >si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > >List technical documents are available at: > http://www.si-list.net > >List archives are viewable at: > //www.freelists.org/archives/si-list > >Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > > >------------------------------------------------------------------ >To unsubscribe from si-list: >si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field > >or to administer your membership from a web page, go to: >//www.freelists.org/webpage/si-list > >For help: >si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field > > >List technical documents are available at: > http://www.si-list.net > >List archives are viewable at: > //www.freelists.org/archives/si-list > >Old (prior to June 6, 2001) list archives are viewable at: > http://www.qsl.net/wb6tpu > > >------------------------------------------------------------------ To unsubscribe from si-list: si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field or to administer your membership from a web page, go to: //www.freelists.org/webpage/si-list For help: si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field List technical documents are available at: http://www.si-list.net List archives are viewable at: //www.freelists.org/archives/si-list Old (prior to June 6, 2001) list archives are viewable at: http://www.qsl.net/wb6tpu