[SI-LIST] AW: [EXTERNAL] the maximum value of coupling capacitors

  • From: "Havermann Gert" <dmarc-noreply@xxxxxxxxxxxxx> ("Gert.Havermann")
  • To: SI-LIST <si-list@xxxxxxxxxxxxx>
  • Date: Tue, 21 Feb 2023 08:57:56 +0000

Chambers,
inrush current is not only a hot-plug effect. Each bit after a longer idle time 
will have the same effect.

BR
Gert


----------------------------------------
HARTING Electric Stiftung & Co. KG | Postfach 14 73, 32328 Espelkamp | 
Wilhelm-Harting-Straße 1, 32339 Espelkamp | www.HARTING.com
Pers. haftende Gesellschafterin: HARTING Stiftung & Co. KG, pers. haftende 
Gesellschafterin: HARTING Führungsstiftung
Vorstand: Dipl.-Kfm. Philip F. W. Harting (Vorsitzender), Dipl.-Kffr. Maresa W. 
M. Harting-Hertz, Dipl.-Kfm., Dr.-Ing. E. h. Dietmar Harting, Dipl.-Hdl. 
Margrit Harting, Dr.-Ing. Kurt D. Bettenhausen, Dipl.-Ing. (FH) 
Dipl.-Wirtsch.-Ing. (FH) Andreas Conrad, Ass. iur. Doris Höpfl
Sitz der Gesellschaft: Espelkamp | Amtsgericht Bad Oeynhausen | Register-Nr. 
HRA 5602 | UST-Id Nr. DE813265676 | WEEE-Reg.-Nr. DE 56507374

-----Ursprüngliche Nachricht-----
Von: si-list-bounce@xxxxxxxxxxxxx <si-list-bounce@xxxxxxxxxxxxx> Im Auftrag von 
Chambers yin
Gesendet: Dienstag, 21. Februar 2023 07:33
An: SI-LIST <si-list@xxxxxxxxxxxxx>
Betreff: [EXTERNAL] [SI-LIST] the maximum value of coupling capacitors

Hello experts,
Yesterday I went through the details of the maximum value of coupling 
capacitors defined in IEEE802.3. For 10GBase-KR signal, "It is recommended that 
the maximum value of the coupling capacitors be limited to 100nF. This will 
limit the inrush currents to the receiver that could damage the receiver 
circuits when repeatedly connected to transmit modules with a high voltage 
level ". Based on this description, I am confused on two items:
1. Why is there no limitation about minimum value? DC wander effect is a big 
concern, which it is widely discussed during SI-LIST group? 2. In general, 
hot plug will result in inrush current, for example USB. Why should inrush 
current be taken into account for 10GBase-KR (backplane application)?
Br,
-Chambers

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List forum  is accessible at:
               http://tech.groups.yahoo.com/group/si-list

List archives are viewable at:     
                //www.freelists.org/archives/si-list
 
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts:

  • » [SI-LIST] AW: [EXTERNAL] the maximum value of coupling capacitors - Havermann Gert