I have one new thing to say about AC-couple capacitors: they can now be used 
as test points for serial protocol analysis tools.  There are probing 
methods which can temporarily attach directly (solder) to the end caps of a 
pair of AC capacitors.

A disposable "flex tip" probe head solders to the capacitor pair.  It can 
then connect to a Flying Lead
(manufactured by SAMTEC.... see the "Spirit FL" ).

Our serial bus probes include this as a probing option.

Paul Taddonio
www.futureplus.com



----- Original Message ----- 
From: "Kotson, Michael" <mkotson@xxxxxxxxxxx>
To: <liuluping@xxxxxxxxxx>; <si-list@xxxxxxxxxxxxx>
Cc: <oukanghua@xxxxxxxxxx>
Sent: Friday, January 18, 2008 10:40 AM
Subject: [SI-LIST] Re: How to place the AC coupling capacitor of the serdes?


Hi Liu,
   I have done designs both ways with PCIe, and didn't notice much of a
difference in the compliance tests between RX and TX ends.  Both were
able to pass without issue.  It's always best to simulate first if you
can.=20

Best of luck,
Mike

-----Original Message-----
From: si-list-bounce@xxxxxxxxxxxxx [mailto:si-list-bounce@xxxxxxxxxxxxx]
On Behalf Of liuluping 41830
Sent: Thursday, January 17, 2008 9:11 PM
To: si-list@xxxxxxxxxxxxx
Cc: oukanghua@xxxxxxxxxx
Subject: [SI-LIST] How to place the AC coupling capacitor of the serdes?

Dear si-listers:
AC coupling per the PCI Express Base Specification Revision 1.0a,
section 4.3.1.2 dictates AC coupling to be placed as
close as practical to the transmitter buffer.=20
We consider that the AC cap is used to ensure the DC bias levels of the
transmitted signal do not adversely
affect the receiver,and most of time place it clsoe to the receiver
side.Why the PCIe requires  to put it on the TX side?
Is it differ from different serdes interface?

 Thanks and Regards,

                    LIU Luping

  =20

*****************************************************************
This e-mail and its attachments contain confidential information from
HUAWEI, which is intended only for the person or entity whose address is
listed above. Any use of the information contained herein in any way
(including, but not limited to, total or partial disclosure,
reproduction, or dissemination) by persons other than the intended
recipient(s) is prohibited. If you receive this e-mail in error, please
notify the sender by phone or em
ail immediately and delete it!
*****************************************************************

------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:    =20
//www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
  http://www.qsl.net/wb6tpu
 =20


*****************************************************************
*************
CONFIDENTIAL NOTE: This e-mail and any attachments may be
confidential and protected by legal privilege. If you are not
the intended recipient, be aware that you are hereby notified
that any unauthorized review, use, disclosure, dissemination,
distribution, or copying of this communication, or any of its
contents, is strictly prohibited. If you have received this
email in error, please notify us immediately by replying to the
sender and deleting this copy and the reply from your system.
Thank you for your cooperation.

EXPORT CONTROLLED DOCUMENT
This document may contain information whose export is restricted
by the Arms Export Control Act (Title 22, U.S.C., Sec 2751 Et
Seq.) or the Export Administration Act of 1979, as amended,
(Title 50, U.S.C., App. 2401, Et. Seq.) Violations to these
export laws are subject to severe criminal penalties.

All technical data forwarded by VT Miltope to its suppliers is
EXPORT CONTROLLED. Supplier shall not disclose technical data in
any form to a Foreign Person (including foreign person employees
of Supplier), or export the technical data from the United
States without U.S. Government authority and the written
authorization of VT Miltope Contracts Department.
*****************************************************************
*************
------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:
//www.freelists.org/archives/si-list
or at our remote archives:
http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
  http://www.qsl.net/wb6tpu



------------------------------------------------------------------
To unsubscribe from si-list:
si-list-request@xxxxxxxxxxxxx with 'unsubscribe' in the Subject field

or to administer your membership from a web page, go to:
//www.freelists.org/webpage/si-list

For help:
si-list-request@xxxxxxxxxxxxx with 'help' in the Subject field


List technical documents are available at:
                http://www.si-list.net

List archives are viewable at:     
                //www.freelists.org/archives/si-list
or at our remote archives:
                http://groups.yahoo.com/group/si-list/messages
Old (prior to June 6, 2001) list archives are viewable at:
                http://www.qsl.net/wb6tpu
  

Other related posts:

  • » [SI-LIST] AC coupling capacitor testpoint