No, that wasnt me.  Got mine from Light Bulbs International via Amazon.  They 
are #19 bulbs, $7.49 for a 10-pack.  Still available as far as I know: 
https://www.amazon.com/19-Miniature-Light-Bulb-Pack/dp/B00BQ0CZNI/ref=sr_1_15?ie=UTF8&qid=1509918070&sr=8-15&keywords=19+light+bulb
 
Bob
 
-------------------------------------------------------------------------------------------------
 
Were you the one that bid something like $30.31 for that group of bulbs?   Try 
to buy new ones.  There are many with that same base but not the same voltage.

Not true.  I restocked my Rodgers 770 music rack light with new bulbs I ordered 
off the Internet just two months ago.  They’re not cheap, but they’re certainly 
available.

Bob

On Nov 4, 2017, at 16:58, Mike Jacklin <mikej@xxxxxxxxxxxxxxxxxxxxx> wrote:


You are correct the old style round glass bulbs were done in series.  I suspect 
it was something to do with voltage.  Btw, those bulbs are no longer available 
anywhere.  Rodgers had bought out the last remaining stock from GE many years 
ago.  These bulbs were also the bulbs used in the Lionel Trains.
Mike
 
From: rodgersorgan-bounce@xxxxxxxxxxxxx 
[mailto:rodgersorgan-bounce@xxxxxxxxxxxxx] On Behalf Of CenturyLink Customer
Sent: Friday, November 3, 2017 1:49 PM
To: rodgersorgan@xxxxxxxxxxxxx
Subject: [rodgersorganusers] Re: Rodgers Exeter 770 Analog organ transformer
 
I think on my 1973 Trio the bulbs are wired in a series/parallel manner.  Sets 
of 2 bulbs in series  that are parallel with other set of 2 bulbs in parallel.  
I noticed several times when  I replaced one bulb the one next to it would 
glow.  Strange system.
JJS

Correct but keep in mind if they used a higher voltage bulb on the pedal and 
melted the wiring oops!  Regarding the music rack, look for that dimmer, either 
up by the keyboards or under the keyboards.  Lots of organists turned them down 
to save on the bulbs.
 
From: rodgersorgan-bounce@xxxxxxxxxxxxx 
[mailto:rodgersorgan-bounce@xxxxxxxxxxxxx] On Behalf Of D. Resor
Sent: Friday, November 3, 2017 5:19 AM
To: rodgersorgan@xxxxxxxxxxxxx
Subject: [rodgersorganusers] Re: Rodgers Exeter 770 Analog organ transformer
 
Mike,
 
I missed the reply you first made.  This makes perfect sense.  If the organ 
functions/plays normally then I do not see it to be a power supply emergency at 
this point.
 
To be on the safe side if replacing the lamps with the correct bulbs does not 
repair the problem, the power supply DC voltages should be checked by someone 
knowledgeable of the technology.
 
 
Donald R. Resor Jr. T. W. & T. C. Svc. Co.
http://hammondorganservice.com
Hammond USA warranty service
"Most people don’t have a sense of humor. They think they do, but they don’t." 
--Jonathan Winters
 
 
 
From: rodgersorgan-bounce@xxxxxxxxxxxxx 
[mailto:rodgersorgan-bounce@xxxxxxxxxxxxx] On Behalf Of Mike Jacklin
Sent: Thursday, November 02, 2017 9:27 AM
To: rodgersorgan@xxxxxxxxxxxxx
Subject: [rodgersorganusers] Re: Rodgers Exeter 770 Analog organ transformer
 
His pedal bulbs are out, I told him to check to see if they were burned out, 
they are the old type car bulbs and folks put higher wattage than they should 
at times.  I told him to check to see if connections were melted.  Also his 
music rack lights are dim,  told him to check for a dimmer switch and or bad 
grounds.
Mike
 
From: rodgersorgan-bounce@xxxxxxxxxxxxx 
[mailto:rodgersorgan-bounce@xxxxxxxxxxxxx] On Behalf Of D. Resor
Sent: Thursday, November 2, 2017 4:42 AM
To: rodgersorgan@xxxxxxxxxxxxx
Subject: [rodgersorganusers] Re: Rodgers Exeter 770 Analog organ transformer
 
You should be able to measure the DC voltages from the terminal strips where 
the cabling attaches to the power supply pwbs.  If any of those voltages are 
greatly below spec then the complete chassis would have to be disconnected and 
removed for further testing/repairs done.
 
What are the problems/symptoms?
 
 
Donald R. Resor Jr. T. W. & T. C. Svc. Co.
http://hammondorganservice.com
Hammond USA warranty service
"Most people don’t have a sense of humor. They think they do, but they don’t." 
--Jonathan Winters
 
 
 
 
 
From: rodgersorgan-bounce@xxxxxxxxxxxxx 
[mailto:rodgersorgan-bounce@xxxxxxxxxxxxx] On Behalf Of Paul Roy
Sent: Wednesday, November 01, 2017 1:00 PM
To: rodgersorgan@xxxxxxxxxxxxx
Subject: [rodgersorganusers] Rodgers Exeter 770 Analog organ transformer
 
Can the transformer be removed for testing without removing the entire power 
supply chassis?
 
Thank you


 
--

Paul F. Roy

Other related posts: