Re: sys password change in dataguard

  • From: Kumar Madduri <ksmadduri@xxxxxxxxx>
  • To: kp0773@xxxxxxxxx
  • Date: Tue, 8 Mar 2011 18:03:58 -0800

At our place, we just copied the password file before the next redo log
transport and log shipping was ok


 On Tue, Mar  8, 2011 at 4:11 PM, K R <kp0773@xxxxxxxxx> wrote:

> All,
>
> We have a need to change the sys user password in primary . and we have
> recently put a standby in place.
>
> so what will be the recommended way to change the sys user password so that
> it wont break the physical standby .
>
> on 11g doc it says
>  9.3.7 Refresh the Password File
>
> If the REMOTE_LOGIN_PASSWORDFILE database initialization parameter is set
> to SHARED or EXCLUSIVE, the password file on a physical standby database
> must be replaced with a fresh copy from the primary database after granting
> or revoking administrative privileges or changing the password of a user
> with administrative privileges.
>
> Failure to refresh the password file on the physical standby database MAY
>  cause authentication of redo transport sessions or connections as SYSDBA or
> SYSOPER to the physical standby database to fail.
>
>
> however  it says it may cause to fail  which confuses me .
> appreciate any suggestion.
>
> thanks
> Kart
>