Thanks Mathew and Andy. Just want to make sure it is not an issue for Physical
Standby. True for Failover scenario and so is the reason mentioned switchover
explicitly. Failover can surely add some issue.
Sanjay
On Wednesday, June 1, 2016 12:53 PM, Andy Klock <andy@xxxxxxxxxxxxxxx>
wrote:
Physical or Logical standbys? Physical should work as expected, but logicals
need to be considered:
https://docs.oracle.com/cd/E11882_01/server.112/e41134/manage_ls.htm#SBYDB4833
On Wed, Jun 1, 2016 at 12:13 PM, Sanjay Mishra <dmarc-noreply@xxxxxxxxxxxxx>
wrote:
Has anyone used MV with Dataguard ?
If I had MV log on Primary and does the Standby will also have Data refreshed
in both base tables as well as MV logs ?If MV log has the data, then Can we use
it after switchover to Dataguard to Fast refresh the Target remote Database
MV's ?
TIASanjay