Re: Got Questions: Golden Gate replication between cloned environments

  • From: Chris Taylor <christopherdtaylor1994@xxxxxxxxx>
  • To: Dave Herring <gdherri@xxxxxxxxx>
  • Date: Fri, 1 Dec 2017 09:02:42 -0600

Additional details.

1. To clone the environments we snapshot the storage protection group and
provide the snapshot as the cloned db (Pure Storage Array - take snapshot
of Prod Disk Group, and mount that snapshot on Dev/Staging/QA servers as a
dev/staging or QA database)
The cloned copies (OLTP and DW) are in sync initially but eventually the
OLTP and DW Dev/Staging/QA environments get out of sync:

OLTP Prod -- GGate --> DW Prod
(Clone Copies Below)
OLTP Dev  --> DW Dev (no GGate)
OLTP Staging --> DW Staging (no GGate)
OLTP QA --> DW QA (no GGate)


2. Env:
DB = 12.1.0.2 64-bit
OS = RHEL 7
GGate Version = 12.1.2.1.170117



On Fri, Dec 1, 2017 at 8:46 AM, Dave Herring <gdherri@xxxxxxxxx> wrote:

Through in a few version and env details while you're at it.  I wouldn't
think your scenario would be impacted to much with the release but we've
had different issues where the release was critical in getting the
requirement to work.

On Fri, Dec 1, 2017 at 8:42 AM, Ls Cheng <exriscer@xxxxxxxxx> wrote:

Hi Chris

I have setup in a few environments where QA environment is refreshed
using Storage Snapshots, works good. How are you refreshing the
environments?

Thank you


On Fri, Dec 1, 2017 at 3:38 PM, Chris Taylor <
christopherdtaylor1994@xxxxxxxxx> wrote:

We have Golden Gate replication in production and there is some
discussion about using Golden Gate replication in the cloned production
copies (Dev, Staging, QA).

We refresh Dev/Staging/QA monthly.

I don't know Golden Gate very well (beginner/intermediate) but I'm
thinking this won't work in the cloned environments as the clones would
lose the Golden Gate Extract process each time the clone happened and the
SCNs would get out of sync anyway.

Questions
1. Am I wrong in thinking this?
2. Is there a way to keep Golden Gate running in cloned environments
without a lot of manual intervention?

I'd like to hear any of the technical issues related to such a setup.

Thanks,
Chris





--
Dave

Other related posts: