Yes, Barb, we still develop FA film (and you thought there was no sanity claus). Have your inquirer call us at 617-964-5067 or check our web page (easiest way is to google "angiographics" - we should be the 2nd or third hit). Unfortunately, someone cybersquatted angiographics.com years ago and refuses to relinquish it for less than $250,000. Marty Rothenberg angiographics, inc. PS- I assume this is an acceptable form of advertising on optimal, because our processing business is now non-profit. -----Original Message----- From: FreeLists Mailing List Manager <ecartis@xxxxxxxxxxxxx> To: optimal digest users <ecartis@xxxxxxxxxxxxx> Sent: Thu, Dec 19, 2013 1:15 am Subject: optimal Digest V4 #237 optimal Digest Wed, 18 Dec 2013 Volume: 04 Issue: 237 In This Issue: [optimal] Re: Developing FA Film [optimal] Re: Developing FA Film [optimal] Re: Developing FA Film [optimal] Apologies/ [optimal] Re: Apologies/ [optimal] Re: Apologies/ [optimal] Re: Apologies/ [optimal] Re: Haag-Streit PBQ-900 ---------------------------------------------------------------------- From: "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> Subject: [optimal] Re: Developing FA Film Date: Wed, 18 Dec 2013 21:41:46 +0000 Hello Allen, I'm still unable to view images from viewing stations.... What should I do? Andy Sanchez, COA Ophthalmic Photographer 210-358-7631 Eye Clinic-TDI 701 S. Zarzamora San Antonio, TX 78207 Sancheza6@xxxxxxxxxxx From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz Sent: Tuesday, January 10, 2012 5:36 PM To: optimal Subject: [optimal] Re: Developing FA Film Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers Allen R Katz, FOPS CRA COT OCT-C CRA Section Chair PO Box 24147 Omaha NE 68124-0147 Telephone: 402-598-0925 NEW FAX NUMBER: 888-803-0191 > Subject: [optimal] Re: Developing FA Film > Date: Mon, 9 Jan 2012 13:38:08 -0800 > From: cpmceyelab@xxxxxxxxxxxxxxxx<mailto:cpmceyelab@xxxxxxxxxxxxxxxx> > To: optimal@xxxxxxxxxxxxx<mailto:optimal@xxxxxxxxxxxxx> > > Sure. I have a Wing Lynch machine back here in my cave...haha. > > Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS > Ophthalmic Diagnostic Center > CPMC Department of Ophthalmology > 2100 Webster Street Suite 212 > San Francisco CA 94115 > (415) 600-3937 FAX (415) 600-6563 > > -----Original Message----- > From: optimal-bounce@xxxxxxxxxxxxx<mailto:optimal-bounce@xxxxxxxxxxxxx> [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx<mailto:ops@xxxxxxxxxx> > Sent: Monday, January 09, 2012 12:32 PM > To: optimal@xxxxxxxxxxxxx<mailto:optimal@xxxxxxxxxxxxx> > Subject: [optimal] Developing FA Film > > Everyone: > > I received the following inquiry today and thought I would ask the experts > before I reply to this physician. > "Can you please help me find someone to develop my fluorescein angiography > film 400TX?" > > Thanks for your help. > > Barbara McCalley > OPS Executive Director > ops@xxxxxxxxxx<mailto:ops@xxxxxxxxxx> > 800-403-1677 > > ------------------------------ Subject: [optimal] Re: Developing FA Film From: Allen Katz <alkatz2000@xxxxxxxxx> Date: Wed, 18 Dec 2013 15:46:35 -0600 What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help Allen R. Katz, FOPS, CRA, OCT-C, COT Application Specialist Heidelberg Engineering, Inc. Cell: 402-305-9818 Fax: 888-803-0191 Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx > On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> wrote: > > Hello Allen, > I’m still unable to view images from viewing stations…. What should I do? > > Andy Sanchez, COA > Ophthalmic Photographer > 210-358-7631 > Eye Clinic-TDI > 701 S. Zarzamora > San Antonio, TX 78207 > Sancheza6@xxxxxxxxxxx > > From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz > Sent: Tuesday, January 10, 2012 5:36 PM > To: optimal > Subject: [optimal] Re: Developing FA Film > > Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers > > > Allen R Katz, FOPS > CRA COT OCT-C > > CRA Section Chair > PO Box 24147 > Omaha NE 68124-0147 > > Telephone: 402-598-0925 > > NEW FAX NUMBER: 888-803-0191 > > > > > > > > Subject: [optimal] Re: Developing FA Film > > Date: Mon, 9 Jan 2012 13:38:08 -0800 > > From: cpmceyelab@xxxxxxxxxxxxxxxx > > To: optimal@xxxxxxxxxxxxx > > > > Sure. I have a Wing Lynch machine back here in my cave...haha. > > > > Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS > > Ophthalmic Diagnostic Center > > CPMC Department of Ophthalmology > > 2100 Webster Street Suite 212 > > San Francisco CA 94115 > > (415) 600-3937 FAX (415) 600-6563 > > > > -----Original Message----- > > From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx > > Sent: Monday, January 09, 2012 12:32 PM > > To: optimal@xxxxxxxxxxxxx > > Subject: [optimal] Developing FA Film > > > > Everyone: > > > > I received the following inquiry today and thought I would ask the experts > > before I reply to this physician. > > "Can you please help me find someone to develop my fluorescein angiography > > film 400TX?" > > > > Thanks for your help. > > > > Barbara McCalley > > OPS Executive Director > > ops@xxxxxxxxxx > > 800-403-1677 > > > > ------------------------------ Date: Wed, 18 Dec 2013 14:22:50 -0800 (PST) From: John Gerty <gertyjm@xxxxxxxxx> Subject: [optimal] Re: Developing FA Film We appear to have a crossed thread here. In response to film processing: Try Angiographics: http://www.mobile-eye-fa.com/history.htm or Justice Angiographics: http://www.justiceop.com/file/Home.html JMGerty (now with a brand new right knee) On Wednesday, December 18, 2013 3:47 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help > > >Allen R. Katz, FOPS, >CRA, OCT-C, COT >Application Specialist >Heidelberg Engineering, Inc. > > >Cell: 402-305-9818 >Fax: 888-803-0191 >Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx > >On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> wrote: > > >Hello Allen, >I’m still unable to view images from viewing stations…. What should I do? > >Andy Sanchez, COA >Ophthalmic Photographer >210-358-7631 >Eye Clinic-TDI >701 S. Zarzamora >San Antonio, TX 78207 >Sancheza6@xxxxxxxxxxx > >From:optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz >Sent: Tuesday, January 10, 2012 5:36 PM >To: optimal >Subject: [optimal] Re: Developing FA Film > >Perhaps the imager is the adventurous sort. I am cleaning out the basement >and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers > > >Allen R Katz, FOPS >CRA COT OCT-C > >CRA Section Chair >PO Box 24147 >Omaha NE 68124-0147 > >Telephone: 402-598-0925 > >NEWFAX NUMBER: 888-803-0191 > > > > > > >> Subject: [optimal] Re: Developing FA Film >> Date: Mon, 9 Jan 2012 13:38:08 -0800 >> From: cpmceyelab@xxxxxxxxxxxxxxxx >> To: optimal@xxxxxxxxxxxxx >> >> Sure. I have a Wing Lynch machine back here in my cave...haha. >> >> Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS >> Ophthalmic Diagnostic Center >> CPMC Department of Ophthalmology >> 2100 Webster Street Suite 212 >> San Francisco CA 94115 >> (415) 600-3937 FAX (415) 600-6563 >> >> -----Original Message----- >> From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx >> Sent: Monday, January 09, 2012 12:32 PM >> To: optimal@xxxxxxxxxxxxx >> Subject: [optimal] Developing FA Film >> >> Everyone: >> >> I received the following inquiry today and thought I would ask the experts >> before I reply to this physician. >> "Can you please help me find someone to develop my fluorescein angiography >> film 400TX?" >> >> Thanks for your help. >> >> Barbara McCalley >> OPS Executive Director >> ops@xxxxxxxxxx >> 800-403-1677 >> >> > > ------------------------------ Subject: [optimal] Apologies/ From: Allen Katz <alkatz2000@xxxxxxxxx> Date: Wed, 18 Dec 2013 16:28:25 -0600 For unintended clutter > On Dec 18, 2013, at 4:22 PM, John Gerty <gertyjm@xxxxxxxxx> wrote: > > We appear to have a crossed thread here. > > In response to film processing: > > Try Angiographics: http://www.mobile-eye-fa.com/history.htm > > or Justice Angiographics: http://www.justiceop.com/file/Home.html > > JMGerty (now with a brand new right knee) > > > On Wednesday, December 18, 2013 3:47 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: > What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help > > Allen R. Katz, FOPS, > CRA, OCT-C, COT > Application Specialist > Heidelberg Engineering, Inc. > > Cell: 402-305-9818 > Fax: 888-803-0191 > Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx > >> On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> wrote: >> > > Hello Allen, > I’m still unable to view images from viewing stations…. What should I do? > > Andy Sanchez, COA > Ophthalmic Photographer > 210-358-7631 > Eye Clinic-TDI > 701 S. Zarzamora > San Antonio, TX 78207 > Sancheza6@xxxxxxxxxxx > > From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz > Sent: Tuesday, January 10, 2012 5:36 PM > To: optimal > Subject: [optimal] Re: Developing FA Film > > Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers > > > Allen R Katz, FOPS > CRA COT OCT-C > > CRA Section Chair > PO Box 24147 > Omaha NE 68124-0147 > > Telephone: 402-598-0925 > > NEW FAX NUMBER: 888-803-0191 > > > > > > Subject: [optimal] Re: Developing FA Film > > Date: Mon, 9 Jan 2012 13:38:08 -0800 > > From: cpmceyelab@xxxxxxxxxxxxxxxx > > To: optimal@xxxxxxxxxxxxx > > > > Sure. I have a Wing Lynch machine back here in my cave...haha. > > > > Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS > > Ophthalmic Diagnostic Center > > CPMC Department of Ophthalmology > > 2100 Webster Street Suite 212 > > San Francisco CA 94115 > > (415) 600-3937 FAX (415) 600-6563 > > > > -----Original Message----- > > From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx > > Sent: Monday, January 09, 2012 12:32 PM > > To: optimal@xxxxxxxxxxxxx > > Subject: [optimal] Developing FA Film > > > > Everyone: > > > > I received the following inquiry today and thought I would ask the experts > > before I reply to this physician. > > "Can you please help me find someone to develop my fluorescein angiography > > film 400TX?" > > > > Thanks for your help. > > > > Barbara McCalley > > OPS Executive Director > > ops@xxxxxxxxxx > > 800-403-1677 > > > > > > ------------------------------ Date: Wed, 18 Dec 2013 19:23:27 -0800 (PST) From: Ray Gardner <raygardner99@xxxxxxxxx> Subject: [optimal] Re: Apologies/ I keep getting an error when I dip the PC in the fixer. Somehow I cant get it to developed, smoke and sparks also. G. Ray Gardner, CRA, OCT-C, CDOS, COA, OSA, RMA Southwest Retina Specialists 7411 Wallace Blvd. Amarillo, Texas 79106 office (806)351-1870 fax (806)351-1690 cell (806)676-9793 email: raygardner99@xxxxxxxxx On Wednesday, December 18, 2013 4:29 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: For unintended clutter On Dec 18, 2013, at 4:22 PM, John Gerty <gertyjm@xxxxxxxxx> wrote: We appear to have a crossed thread here. > > >In response to film processing: > > >Try Angiographics: http://www.mobile-eye-fa.com/history.htm > > > or Justice Angiographics: http://www.justiceop.com/file/Home.html > >JMGerty (now with a brand new right knee) > > > >On Wednesday, December 18, 2013 3:47 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: > >What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help >> >> >>Allen R. Katz, FOPS, >>CRA, OCT-C, COT >>Application Specialist >>Heidelberg Engineering, Inc. >> >> >>Cell: 402-305-9818 >>Fax: 888-803-0191 >>Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx >> >>On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> wrote: >> >> >>Hello Allen, >>I’m still unable to view images from viewing stations…. What should I do? >> >>Andy Sanchez, COA >>Ophthalmic Photographer >>210-358-7631 >>Eye Clinic-TDI >>701 S. Zarzamora >>San Antonio, TX 78207 >>Sancheza6@xxxxxxxxxxx >> >>From:optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz >>Sent: Tuesday, January 10, 2012 5:36 PM >>To: optimal >>Subject: [optimal] Re: Developing FA Film >> >>Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers >> >> >>Allen R Katz, FOPS >>CRA COT OCT-C >> >>CRA Section Chair >>PO Box 24147 >>Omaha NE 68124-0147 >> >>Telephone: 402-598-0925 >> >>NEWFAX NUMBER: 888-803-0191 >> >> >> >> >> >> >>> Subject: [optimal] Re: Developing FA Film >>> Date: Mon, 9 Jan 2012 13:38:08 -0800 >>> From: cpmceyelab@xxxxxxxxxxxxxxxx >>> To: optimal@xxxxxxxxxxxxx >>> >>> Sure. I have a Wing Lynch machine back here in my cave...haha. >>> >>> Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS >>> Ophthalmic Diagnostic Center >>> CPMC Department of Ophthalmology >>> 2100 Webster Street Suite 212 >>> San Francisco CA 94115 >>> (415) 600-3937 FAX (415) 600-6563 >>> >>> -----Original Message----- >>> From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx >>> Sent: Monday, January 09, 2012 12:32 PM >>> To: optimal@xxxxxxxxxxxxx >>> Subject: [optimal] Developing FA Film >>> >>> Everyone: >>> >>> I received the following inquiry today and thought I would ask the experts >>> before I reply to this physician. >>> "Can you please help me find someone to develop my fluorescein angiography >>> film 400TX?" >>> >>> Thanks for your help. >>> >>> Barbara McCalley >>> OPS Executive Director >>> ops@xxxxxxxxxx >>> 800-403-1677 >>> >>> >> >> ------------------------------ From: "Aletter, Karin" <AletterKarin@xxxxxxxx> Subject: [optimal] Re: Apologies/ Date: Thu, 19 Dec 2013 03:31:10 +0000 Have you tried Stopbath? Sent from my iPhone On Dec 18, 2013, at 21:23, "Ray Gardner" <raygardner99@xxxxxxxxx<mailto:raygardner99@xxxxxxxxx>> wrote: I keep getting an error when I dip the PC in the fixer. Somehow I cant get it to developed, smoke and sparks also. G. Ray Gardner, CRA, OCT-C, CDOS, COA, OSA, RMA Southwest Retina Specialists 7411 Wallace Blvd. Amarillo, Texas 79106 office (806)351-1870 fax (806)351-1690 cell (806)676-9793 email: raygardner99@xxxxxxxxx<mailto:raygardner99@xxxxxxxxx> On Wednesday, December 18, 2013 4:29 PM, Allen Katz <alkatz2000@xxxxxxxxx<mailto:alkatz2000@xxxxxxxxx>> wrote: For unintended clutter On Dec 18, 2013, at 4:22 PM, John Gerty <gertyjm@xxxxxxxxx<mailto:gertyjm@xxxxxxxxx>> wrote: We appear to have a crossed thread here. In response to film processing: Try Angiographics: http://www.mobile-eye-fa.com/history.htm or Justice Angiographics: http://www.justiceop.com/file/Home.html JMGerty (now with a brand new right knee) On Wednesday, December 18, 2013 3:47 PM, Allen Katz <alkatz2000@xxxxxxxxx<mailto:alkatz2000@xxxxxxxxx>> wrote: What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help Allen R. Katz, FOPS, CRA, OCT-C, COT Application Specialist Heidelberg Engineering, Inc. Cell: 402-305-9818 Fax: 888-803-0191 Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx<mailto:allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx> On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx<mailto:sancheza6@xxxxxxxxxxx>> wrote: Hello Allen, I�m still unable to view images from viewing stations�. What should I do? Andy Sanchez, COA Ophthalmic Photographer 210-358-7631 Eye Clinic-TDI 701 S. Zarzamora San Antonio, TX 78207 Sancheza6@xxxxxxxxxxx<mailto:Sancheza6@xxxxxxxxxxx> From: optimal-bounce@xxxxxxxxxxxxx<mailto:optimal-bounce@xxxxxxxxxxxxx> [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz Sent: Tuesday, January 10, 2012 5:36 PM To: optimal Subject: [optimal] Re: Developing FA Film Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers Allen R Katz, FOPS CRA COT OCT-C CRA Section Chair PO Box 24147 Omaha NE 68124-0147 Telephone: 402-598-0925 NEW FAX NUMBER: 888-803-0191 > Subject: [optimal] Re: Developing FA Film > Date: Mon, 9 Jan 2012 13:38:08 -0800 > From: cpmceyelab@xxxxxxxxxxxxxxxx<mailto:cpmceyelab@xxxxxxxxxxxxxxxx> > To: optimal@xxxxxxxxxxxxx<mailto:optimal@xxxxxxxxxxxxx> > > Sure. I have a Wing Lynch machine back here in my cave...haha. > > Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS > Ophthalmic Diagnostic Center > CPMC Department of Ophthalmology > 2100 Webster Street Suite 212 > San Francisco CA 94115 > (415) 600-3937 FAX (415) 600-6563 > > -----Original Message----- > From: optimal-bounce@xxxxxxxxxxxxx<mailto:optimal-bounce@xxxxxxxxxxxxx> [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of ops@xxxxxxxxxx<mailto:ops@xxxxxxxxxx> > Sent: Monday, January 09, 2012 12:32 PM > To: optimal@xxxxxxxxxxxxx<mailto:optimal@xxxxxxxxxxxxx> > Subject: [optimal] Developing FA Film > > Everyone: > > I received the following inquiry today and thought I would ask the experts > before I reply to this physician. > "Can you please help me find someone to develop my fluorescein angiography > film 400TX?" > > Thanks for your help. > > Barbara McCalley > OPS Executive Director > ops@xxxxxxxxxx<mailto:ops@xxxxxxxxxx> > 800-403-1677 > > ---------------------------------------------------------------------- Confidentiality Notice: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. ------------------------------ Date: Wed, 18 Dec 2013 19:38:22 -0800 (PST) From: Ray Gardner <raygardner99@xxxxxxxxx> Subject: [optimal] Re: Apologies/ Shockingly yes, but the Heidelberg camera caught on fire. O well its only same cost as a Ferrari. LOL G. Ray Gardner, CRA, OCT-C, CDOS, COA, OSA, RMA Southwest Retina Specialists 7411 Wallace Blvd. Amarillo, Texas 79106 office (806)351-1870 fax (806)351-1690 cell (806)676-9793 email: raygardner99@xxxxxxxxx On Wednesday, December 18, 2013 9:31 PM, "Aletter, Karin" <AletterKarin@xxxxxxxx> wrote: Have you tried Stopbath? Sent from my iPhone On Dec 18, 2013, at 21:23, "Ray Gardner" <raygardner99@xxxxxxxxx> wrote: I keep getting an error when I dip the PC in the fixer. Somehow I cant get it to developed, smoke and sparks also. > >G. Ray Gardner, CRA, OCT-C, CDOS, COA, OSA, RMA >Southwest Retina Specialists >7411 Wallace Blvd. >Amarillo, Texas 79106 >office (806)351-1870 >fax (806)351-1690 >cell (806)676-9793 >email: mailto:raygardner99@xxxxxxxxx > > > > >On Wednesday, December 18, 2013 4:29 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: > >For unintended clutter > >On Dec 18, 2013, at 4:22 PM, John Gerty <gertyjm@xxxxxxxxx> wrote: > > >We appear to have a crossed thread here. >> >> >>In response to film processing: >> >> >>Try Angiographics: http://www.mobile-eye-fa.com/history.htm >> >> >> or Justice Angiographics: http://www.justiceop.com/file/Home.html >> >>JMGerty (now with a brand new right knee) >> >> >> >>On Wednesday, December 18, 2013 3:47 PM, Allen Katz <alkatz2000@xxxxxxxxx> wrote: >> >>What error do you get? We saw them yesterday and as long as you see the data and patients folder in the network list it will work. I suspect a network permissions issue see if brandon can help >>> >>> >>>Allen R. Katz, FOPS, >>>CRA, OCT-C, COT >>>Application Specialist >>>Heidelberg Engineering, Inc. >>> >>> >>>Cell: 402-305-9818 >>>Fax: 888-803-0191 >>>Email: allen.katz@xxxxxxxxxxxxxxxxxxxxxxxxx >>> >>>On Dec 18, 2013, at 3:41 PM, "Sanchez, Andres" <sancheza6@xxxxxxxxxxx> wrote: >>> >>> >>> >>>Hello Allen, >>>I’m still unable to view images from viewing stations…. What should I do? >>> >>>Andy Sanchez, COA >>>Ophthalmic Photographer >>>210-358-7631 >>>Eye Clinic-TDI >>>701 S. Zarzamora >>>San Antonio, TX 78207 >>>Sancheza6@xxxxxxxxxxx >>> >>>From:mailto:optimal-bounce@xxxxxxxxxxxxx >>>[mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of Allen R. Katz >>>Sent: Tuesday, January 10, 2012 5:36 PM >>>To: optimal >>>Subject: [optimal] Re: Developing FA Film >>> >>>Perhaps the imager is the adventurous sort. I am cleaning out the basement and have nikkor reels, tanks, timers,and a book of recipes for d-11, stop bath, and fixer if you cannot find these available at your photo supply store (ha). These will be headed for the landfill in 2 days so speak up privately if interested. - Cheers >>> >>> >>>Allen R Katz, FOPS >>>CRA COT OCT-C >>> >>>CRA Section Chair >>>PO Box 24147 >>>Omaha NE 68124-0147 >>> >>>Telephone: 402-598-0925 >>> >>>NEWFAX NUMBER: 888-803-0191 >>> >>> >>> >>> >>> >>> >>>> Subject: [optimal] Re: Developing FA Film >>>> Date: Mon, 9 Jan 2012 13:38:08 -0800 >>>> From: mailto:cpmceyelab@xxxxxxxxxxxxxxxx >>>> To: mailto:optimal@xxxxxxxxxxxxx >>>> >>>> Sure. I have a Wing Lynch machine back here in my cave...haha. >>>> >>>> Denice Barsness, CRA, COMT, ROUB, CDOS, FOPS >>>> Ophthalmic Diagnostic Center >>>> CPMC Department of Ophthalmology >>>> 2100 Webster Street Suite 212 >>>> San Francisco CA 94115 >>>> (415) 600-3937 FAX (415) 600-6563 >>>> >>>> -----Original Message----- >>>> From: mailto:optimal-bounce@xxxxxxxxxxxxx >>>> [mailto:optimal-bounce@xxxxxxxxxxxxx] On Behalf Of mailto:ops@xxxxxxxxxx >>>> Sent: Monday, January 09, 2012 12:32 PM >>>> To: mailto:optimal@xxxxxxxxxxxxx >>>> Subject: [optimal] Developing FA Film >>>> >>>> Everyone: >>>> >>>> I received the following inquiry today and thought I would ask the experts >>>> before I reply to this physician. >>>> "Can you please help me find someone to develop my fluorescein angiography >>>> film 400TX?" >>>> >>>> Thanks for your help. >>>> >>>> Barbara McCalley >>>> OPS Executive Director >>>> mailto:ops@xxxxxxxxxx >>>> 800-403-1677 >>>> >>>> >>> >>> > > ________________________________ Confidentiality Notice: This e-mail message, including any attachments, is for the sole use of the intended recipient(s) and may contain confidential and privileged information. Any unauthorized review, use, disclosure or distribution is prohibited. If you are not the intended recipient, please contact the sender by reply e-mail and destroy all copies of the original message. ------------------------------ From: Angela Chappell <angela.chappell@xxxxxxxxxxxxxxx> Subject: [optimal] Re: Haag-Streit PBQ-900 Date: Thu, 19 Dec 2013 05:51:50 +0000 Marshall and interested parties, You wouldn't believe how close you were with your solution! There is a bearing in between the 2 shutters which the technician cleaned and lubricated with WD-40. His technical info didn't state which number H-S lubricant to use for this particular moving part, so he is going to check with Switzerland. Thankfully everything is hunky dory again and maybe it won't seize up again for another 20 years. This is a lovely machine! Kind regards Angela >------------------------------ > >Date: Thu, 12 Dec 2013 09:10:23 -0500 >Subject: [optimal] Re: Haag-Streit PBQ-900 >From: Marshall Tyler <marshalletyler@xxxxxxxxx> > >Think dried out lubrication. If there is a hot viewing lamp nearby, make >sure that it is turned down when not in use... the heat tends to dry out >lubrication. >I use WD-40 to clean out old oil/grease, and then re-lubricate it with the >proper oil. >Let us know what the H-S tech finds. >Good luck, >*Marshall* >Marshall E Tyler > sv *Silk* >On Thu, Dec 12, 2013 at 6:43 AM, Angela Chappell < >angela.chappell@xxxxxxxxxxxxxxx> wrote: > >> My trusty H-S photoslitlamp, which has hardly skipped a beat in the 20 >> years I've been using it, has had a severe aperture malfunction. It >>began >> with getting the odd blown out frame, caused by the aperture not >>shutting >> down, and progressed to it happening on most frames. Have had to limp >>along >> with it until it gets repaired, using the aperture preview to manually >> operate the aperture, and now it is so stiff it's almost seized up. >> >> Before the technician comes tomorrow to completely strip it down, has >> anyone got any advice on what to look for? Are there any bearings in >>there, >> or something which can be lubricated, or might it be the solenoid which >>is >> the problem? >> >> Thanks, Angela -- Angela Chappell Ophthalmic Photographer Flinders Medical Centre Bedford Park SA 5042 Ph 08 82044775 Angela.Chappell@xxxxxxxxxxxxxxx ------------------------------ End of optimal Digest V4 #237 *****************************