I've used the Canon CX-1 non myd, it's really no better than any other
non-myd camera, in that it takes one good image before the pupil closes
down too much to take much else of quality.  Using it with dilation was
fine though.  I also agree that the imaging software for it was clunky.
There didn't seem to be any easy way to do anything on it, and it seemed to
corrupt every AF image I took on it as well. When I called Canon to ask
about rectifying that issue, the rep had no idea what I was talking about.


*Katie Lachut *| (315)806-9733 |  https://www.flickr.com/photos/katielachut
Ophthalmic Photographer with VCU Health System |  RIT 2013


On Thu, Mar 21, 2019 at 11:28 AM CPMC Ophthalmic Diagnostic Center <
dmarc-noreply@xxxxxxxxxxxxx> wrote:



We have a Pictor, it takes a decent image. It works as non-myd but much
easier to use when the patient is dilated... and using the slit lamp
adapter. So you take the hand held camera and mount it on the slit lamp
arm?



There was no software when we purchased (like a digi-cam, the images are
imported into a folder when attached to a computer), unsure if this has
changed. Yes, I think the Paxos software is a nice feature.  I’ve tested
it and it’s easy to use



I'd have a hard time endorsing it as the exposed pins are easily bent when
placing on the charging dock. This happened to ours and even though we had
paid for an extended service agreement we had to pay $1k for the repair. On
top of that, it took about a year to get the device back after agreeing to
pay for the repairs. I notice the Nidek version has the same weak link





The other thing I should add is we can go through 4 fully charged battery
packs in a busy half-day satellite clinic (about 12 FA/FPs) even when the
device is returned to the charger between sessions.





We also have a couple of Canon CX-1 cameras which are closer to a
traditional fundus camera. I have never used them in non-myd mode but I
know its capable. The Image Spectrum review software is a bit clunky... or
maybe I was spoiled by the intuitive functionality of our old OIS software.
Any way, if you go this route I'd recommend paying for Image Spectrum
software and skipping the free RICS software.



Hope this helps,

-cm







On Tue, Mar 19, 2019 at 8:35 PM CPMC Ophthalmic Diagnostic Center <
dmarc-noreply@xxxxxxxxxxxxx> wrote:

Well, of course I have been looking at various smart phone solutions

Lots of problems there, software, working distance, lighting etc



I’m talking a fixed fundus system

And hand held, like the Picktor



Denice Barsness, CRA, COMT, CDOS, FOPS

CPMC Dept of Ophthalmology/ The Eye Institute

Ophthalmic Diagnostic Services

711 Van Ness Avenue Suite 250

San Francisco CA 94109

415-600-5781

FAX 415-558-7011



*From:* Barsness, Denice
*Sent:* Monday, March 18, 2019 6:00 PM
*To:* CPMC Ophthalmic Diagnostic Center <cpmceyelab@xxxxxxxxxxxxxxxx>
*Subject:* FW: [**External**] [optimal] Re: Early morning trivia Fundus
Camera




------------------------------

*From:* optimal-bounce@freelists.orgOn Behalf OfMarshall Tyler
*Sent:* Monday, March 18, 2019 5:59:01 PM (UTC-08:00) Pacific Time (US &
Canada)
*To:* optimal@xxxxxxxxxxxxx
*Subject:* [**External**] [optimal] Re: Early morning trivia Fundus Camera

*WARNING: *This email originated outside of the Sutter Health email
system!
*DO NOT CLICK* links if the sender is unknown and never provide your User
ID or Password.



Think,.... Phone adapters!!

Thank you,
Marshall T.
s/v Silk



On Mon, Mar 18, 2019, 1:19 PM Barsness, Denice <
dmarc-noreply@xxxxxxxxxxxxx> wrote:

What is the least expensive non myd on the market these days, more or less?

And hand held fundus?



D.



Denice Barsness, CRA, COMT, CDOS, FOPS

CPMC Dept of Ophthalmology/ The Eye Institute

Ophthalmic Diagnostic Services

711 Van Ness Avenue Suite 250

San Francisco CA 94109

415-600-5781

FAX 415-558-7011






--

Cory Mangham CRA
Clinical Supervisor - Photography
Austin Retina Associates
801 West 38th Suite 200
Austin, TX 78705

Tel: 512-451-0103 x 4163
Fax: 512-451-2741



CONFIDENTIALITY NOTICE:

PRIVILEGED AND CONFIDENTIAL:  This document and the information contained
herein are confidential and protected from disclosure pursuant to federal
law.  This message is intended only for the use of the Addressee(s) and may
contain information that is PRIVILEGED and CONFIDENTIAL. If you are not the
intended recipient, you are hereby notified that the use, dissemination, or
copying of this information is strictly prohibited.  If you have received
this communication in error, please erase all copies of the message and its
attachments and notify the sender immediately.

Other related posts: