It is technically the ICGA option but utilizing it without the presence of dye.
Hillary
________________________________
From: optimal-bounce@xxxxxxxxxxxxx <optimal-bounce@xxxxxxxxxxxxx> on behalf of
Paul Paquette <dmarc-noreply@xxxxxxxxxxxxx>
Sent: Friday, June 18, 2021 9:59 AM
To: optimal@xxxxxxxxxxxxx <optimal@xxxxxxxxxxxxx>
Subject: [optimal] Re: [External] FAF in the red channel
Correct me if I'm wrong but wouldn't that also be with the red ICG filter on a
fundus camera if equipped (& possibly ICG mode on Optos California)?
I would think there should be some instructions for your specific device in the
study's protocol manual.
Good luck,
Paul Paquette
-----Original Message-----
From: Critser, Douglas B <douglas-critser@xxxxxxxxx>
To: optimal@xxxxxxxxxxxxx <optimal@xxxxxxxxxxxxx>
Sent: Fri, Jun 18, 2021 6:39 am
Subject: [optimal] Re: [External] FAF in the red channel
Eric,
That would be IRAF it’s in the drop down menu of the Spectralis. Screenshot
attached.
Brice Critser CRA, OCT-C, FOPS
Director of Diagnostic Imaging
University of Iowa Hospitals and Clinics
Department of Ophthalmology
From: optimal-bounce@xxxxxxxxxxxxx [mailto:optimal-bounce@xxxxxxxxxxxxx] On ;
Behalf Of Eric Kegley
Sent: Friday, June 18, 2021 8:26 AM
To: optimal@xxxxxxxxxxxxx
Subject: [External] [optimal] FAF in the red channel
Hello all,
I guess I am showing my ignorance but I have a study that is asking if we are
capable of doing FAF in the red channel and I have never heard of such. Can
someone enlighten me?
Thank You,
Eric Kegley, CRA, OCT-C, FOPS, COT
Director of Imaging
Retina Consultants of Texas Research Centers
4460 Bissonnet St, Ste 200
Bellaire, TX 77401
O: 713.524.3434 ext. 4831
D: 713.394-7531
C: 281.236.0215
F: 713.795.4552
RetinaConsultantsTexas.com<https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fwww.retinaconsultantstexas.com%2F&data=04%7C01%7C%7C02f6ff54565b443740ff08d932614c39%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C637596215757339320%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=8qkIOS03pFvm19CdYWch08%2BQkV%2BGW5zLcwyJO63T9CQ%3D&reserved=0>
[cid:image004.png@01D6D05E.55525290]<https://na01.safelinks.protection.outlook.com/?url=http%3A%2F%2Fwww.retinaconsultantstexas.com%2F&data=04%7C01%7C%7C02f6ff54565b443740ff08d932614c39%7C84df9e7fe9f640afb435aaaaaaaaaaaa%7C1%7C0%7C637596215757349274%7CUnknown%7CTWFpbGZsb3d8eyJWIjoiMC4wLjAwMDAiLCJQIjoiV2luMzIiLCJBTiI6Ik1haWwiLCJXVCI6Mn0%3D%7C1000&sdata=VHTkn78vNbXtCkePzCy%2FLWDlXTsQB0%2B%2FWBrREQ%2B%2Fll8%3D&reserved=0>
Notice: This e-mail transmission, and any documents, files or previous e-mail
messages attached to it, may contain confidential or privileged information. If
you are not the intended recipient, or person responsible for delivering it to
the intended recipient, you are hereby notified that any disclosure, copying,
distribution or use of the information contained in or attached to this message
is STRICTLY PROHIBITED. If you have received this transmission in error, please
immediately notify the sender and delete the e-mail and attached documents.
Thank you.
________________________________
Notice: This UI Health Care e-mail (including attachments) is covered by the
Electronic Communications Privacy Act, 18 U.S.C. 2510-2521 and is intended only
for the use of the individual or entity to which it is addressed, and may
contain information that is privileged, confidential, and exempt from
disclosure under applicable law. If you are not the intended recipient, any
dissemination, distribution or copying of this communication is strictly
prohibited. If you have received this communication in error, please notify the
sender immediately and delete or destroy all copies of the original message and
attachments thereto. Email sent to or from UI Health Care may be retained as
required by law or regulation. Thank you.
________________________________