Hi, I'm using Trianglelab T-D500 thermistor on my hotend. I have read issue on
this on Github. https://github.com/KevinOConnor/klipper/issues/3182
In Marlin, it reported temps not below 21 °C even if not heated.
In Klipper, it oscilates from -8 °C upwards when not heated. For now, to avoid
Klipper shutdown, I had set the min_temp to -10 °C.
However, I don't feel safe about this – in case it fails, there is huge
possibility Klipper will not do Thermal shutdown.
Is there a better way to set it via [verify_heater] ? I can't quite understand
options there.