[ibis] Re: Validation of IBIS 5.1 power aware feature

  • From: pankaj gupta <pankaj26492@xxxxxxxxx>
  • To: dmarc-noreply@xxxxxxxxxxxxx
  • Date: Tue, 22 Oct 2019 12:23:28 +0530

Hi Vaibhav,

You just need to tweak B-element call for IBIS in your testbench like
mentioned below:

B1IBIS * Vdd1bio GND1bio* OUTIBIS Pls_IBIS EN_IBIS core_in
+ file=  'file-name.ibis'
+ model= 'model_name'
+ typ=typ
+ buffer=3
*+ power=off*

After turning power=off you can connect Vdd1bio and GND1bio (power and
ground supply for IBIS model) externally to the RLC network like you will
do for spice netlist.

*there can be multiple options in your B-element call which you can leave
unchanged.

Hope it helps.

Thanks
Pankaj Gupta


On Tue, Oct 22, 2019 at 10:01 AM Vaibhav R Katkar <
dmarc-noreply@xxxxxxxxxxxxx> wrote:

Hi All,
I am working on power aware feature of IBIS 5.1 and have a couple of
queries regarding the validation of the final IBIS model as mentioned
below:

1. How to validate the correlation of power aware ibis file(5.1) and the
spice netlist in T2B tool?
2. Is spectre able to simulate power aware ibis file with external
parasitic (R =4mOhm, L=2nH ,C=3pF (in T form)) in the power and ground rail
supply? We are getting convergence issue.

Thanks in advance.
--
Regards,
Vaibhav

Other related posts: