[ibis-quality] IBIS Bug 72 proposal

  • From: "Gregory R Edlund" <gedlund@xxxxxxxxxx>
  • To: ibis-quality@xxxxxxxxxxxxx
  • Date: Mon, 26 Aug 2002 20:29:04 -0500

Dear Fellow IBIS Quality members:

Here's my first stab at the standard load bug report.  Would you like to
review it tomorrow before I post it to the main IBIS reflector?  I can dial
into the conference call tomorrow, but I'll have to leave early due to
other commitments.

Greg



******************************************************************************

********************* IBIS GOLDEN PARSER BUG REPORT FORM
*********************
******************************************************************************


INSTRUCTIONS

To report a bug in the IBIS golden parser.  Please fill out the top part
of the following form and send the complete form to ibischk-bug@xxxxxxxxx

A list of reported bugs will be maintained on vhdl.org.

******************************************************************************


PARSER VERSION NUMBER:
    IBISCHK3 V3.2.5

PLATFORM (SPARC, HP700, PC, etc.):
    RS/6000

OS AND VERSION:
    aix 3 4 000563044C00

REPORTED BY:
    Greg Edlund

DATE:
    26 Aug 2002 original report

DESCRIPTION OF BUG:
    IBIS parser should issue a warning message when Vmeas, Cref, or Vref
    subparameter is missing as each is critical for system-level timing.

INSERT IBIS FILE DEMONSTRATING THE BUG:

[IBIS Ver]      3.2

[File Name]     bug72.ibs

[File Rev]      0.1

[Date]          01/01/00

[Source]        ACME Electronics.com

[Notes]         Do, re, mi.

[Disclaimer]    Use at your own risk, this model bears no resemblance
                to the real component, generated by monkeys, etc.

[Copyright]     Don't you dare copy this!

[Component]     End of life.

[Manufacturer]  Filed chapter 11.

[Package]
|
| variable              typ             min             max
|
R_pkg                   1.0m            NA              NA
L_pkg                   0.01nH          NA              NA
C_pkg                   0.01pF          NA              NA

|
[Pin]   signal_name     model_name      R_pin   L_pin   C_pin
|
  1     in1             bcmos           1.0m    0.01nH  0.01pF
  2     out1            bcmos           1.0m    0.01nH  0.01pF
  3     GND             GND             1.0m    0.01nH  0.01pF
  4     Vdd             POWER           1.0m    0.01nH  0.01pF

|----------------------------------------------------------------------------
| bcmos model definition
|-----------------------------------------------------------------------------
[Model]         bcmos
Model_type      I/O
Polarity        Non-Inverting
Enable          Active-High
Vinl  =         1.15V
Vinh  =         1.35V

| *** PROBLEM AREA:  standard load subparameters are missing.
|Vmeas =         1.25V
|Cref  =         10pF
|Vref  =         0
| ***

|                            typ            min            max
|
C_comp                       1.15pF         1.15pF         1.15pF
[Temperature Range]          55.0           85.0           25.0
[Voltage Range]              2.50V          2.375V         2.625V


[Ramp]
|                            typ            min            max
|
dV/dt_r                      0.836/0.405n   0.723/0.456n   0.958/0.358n
dV/dt_f                      0.834/0.389n   0.744/0.470n   0.930/0.340n
R_load = 50

.
.
.
[End]


(REVISED ERROR MESSAGES FOR REVISE FILE)

IBISCHK3 V3.2.5

Checking bug72.ibs for IBIS 3.2 Compatibility...

WARNING (line   42) - Vmeas subparameter missing from model bcmos.
WARNING (line   42) - Cref subparameter missing from model bcmos.
WARNING (line   42) - Vref subparameter missing from model bcmos.

Errors  : 0
Warnings: 3

File Passed

******************************************************************************

******************** BELOW FOR ADMINISTRATION AND TRACKING
*******************
******************************************************************************


BUG NUMBER: 72

SEVERITY: [FATAL, SEVERE, MODERATE, ANNOYING, ENHANCEMENT]  (ENHANCEMENT)

PRIORITY: [HIGH, MEDIUM, LOW]                               (LOW)

STATUS: [OPEN, CLOSED, WILL NOT FIX, NOT A BUG]             (OPEN)

FIXED VERSION:

FIXED DATE:

NOTES ON BUG FIX:

******************************************************************************

******************************************************************************





---------------------------------------------------------------------
IBIS Quality archives: //www.freelists.org/archives/ibis-quality
To unsubscribe send an email:
  To: ibis-quality-request@xxxxxxxxxxxxx
  Subject: unsubscribe

Other related posts: