[ibis-macro] Re: What part of Legacy IBIS is used by IBIS-AMI

  • From: "Walter Katz" <wkatz@xxxxxxxxxx>
  • To: <Arpad_Muranyi@xxxxxxxxxx>, "'IBIS-ATM'" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Wed, 11 Jul 2012 04:53:11 -0400 (EDT)

I agree.

 

Walter

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Muranyi, Arpad
Sent: Tuesday, July 10, 2012 11:44 PM
To: IBIS-ATM
Subject: [ibis-macro] Re: What part of Legacy IBIS is used by IBIS-AMI

 

That is correct.

 

Arpad

================

 

From: ibis-macro-bounce@xxxxxxxxxxxxx
[mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of Mirmak, Michael
Sent: Tuesday, July 10, 2012 6:07 PM
To: Walter Katz
Cc: IBIS-ATM
Subject: [ibis-macro] Re: What part of Legacy IBIS is used by IBIS-AMI

 

Walter,

 

Thank you!  So, someone using IBIS-AMI models with valid traditional data
in a workflow should expect changes in the IBIS TX C_comp or V-t (or
[Ramp]) data to have an impact on the results provided by the receiver in
an IBIS-AMI-based flow, assuming nothing else changes?

 

-          MM

 

From: Walter Katz [mailto:wkatz@xxxxxxxxxx] 
Sent: Tuesday, July 10, 2012 12:20 PM
To: Mirmak, Michael
Cc: IBIS-ATM
Subject: What part of Legacy IBIS is used by IBIS-AMI

 

MM,

 

The Legacy part of an IBIS model is used to generate the Impulse Response
of the channel. 

 

One method of generating the impulse response is to do a step response,
and take the derivative of the waveform at the Rx input.

 

A simulator uses a combination of the Tx [Voltage Range], C_Comp, IV, VT
and Ramp data, and the Rx C_Comp and IV data. Of course, [External Model]
can also be used by a simulator.

 

The following required Tx IBIS fields are not used in the AMI flow:

Vmeas

The following required Rx IBIS fields are not used in the AMI flow:

Vinl

Vinh

 

Walter

 

 

Walter Katz

wkatz@xxxxxxxxxx

Phone 303.449-2308

Mobile 303.335-6156

 

Other related posts: