David; The reason of separate impulses between victim and aggressor in AMI_Init relies on the approach to approximate Rx with a linear model. Take a Rx that has DFE, you definitely don't want to apply DFE taps on the aggressor impulses. In terms of separating main and aggressor waveforms into AMI_GetWave, I don't agree with you and Arpad. AMI_GetWave models the physical operation of the Rx in real time. A physical Rx receives only one input waveform, which is the combination of main and aggressor signals. Regards, Fangyi From: ibis-macro-bounce@xxxxxxxxxxxxx [mailto:ibis-macro-bounce@xxxxxxxxxxxxx] On Behalf Of David Banas Sent: Tuesday, May 08, 2012 9:18 AM To: 'ibis-macro@xxxxxxxxxxxxx' Subject: [ibis-macro] Send aggressors into GetWave, as well? Hi experts, In the case where we've included aggressors in our call to `AMI_Init', should we also send aggressor waveforms into `AMI_GetWave'? Thanks, David Banas Sr. Member Technical Staff Altera<http://www.altera.com/> +1-408-544-7667 - desk Did you know Altera offers over 150 free online technical training courses<http://www.altera.com/servlets/searchcourse?coursetype=Online&WT.mc_id=t9_ot_mi_mi_tx_a_311>? Take one today! ________________________________ Confidentiality Notice. This message may contain information that is confidential or otherwise protected from disclosure. If you are not the intended recipient, you are hereby notified that any use, disclosure, dissemination, distribution, or copying of this message, or any attachments, is strictly prohibited. If you have received this message in error, please advise the sender by reply e-mail, and delete the message and any attachments. Thank you.