Hello IBIS-AMI on-die S-parameter usage experts,
I'm trying to catch up w/ the latest revisions to the standard in this regard
and have a couple questions:
1. Why was the choice made to use zero Ohms and open circuit for the default
values of: Tx_R and Rx_R, respectively, as opposed to the reference impedance
of the Touchstone data?
2. Is there any explicit language in the current (v7.1) version of the spec.,
which directs the tool vendor to ignore [Power_Clamp]/[GND_Clamp] keywords in
the *.IBS file when Tx_R/Rx_R parameters are encountered in the *.AMI file?
Thanks!
-db
---------------------------------------------------------------------
IBIS Macro website : http://ibis.org/macromodel_wip/
IBIS Macro reflector: //www.freelists.org/list/ibis-macro
To unsubscribe send an email:
To: ibis-macro-request@xxxxxxxxxxxxx
Subject: unsubscribe