[ibis-macro] PAM4 reserved parameter issue/question

  • From: Ambrish Varma <ambrishv@xxxxxxxxxxx>
  • To: 'IBIS-ATM' <ibis-macro@xxxxxxxxxxxxx>
  • Date: Mon, 26 Oct 2020 02:37:51 +0000

Hi All,
We have an issue in the spec about the PAM4 reserved parameters where it 
mentions that
"If the AMI Reserved Parameter Modulation lists "PAM4" (either as a Value or as 
a List selection),
PAM4_UpperThreshold and PAM4_LowerThreshold are required for Rx AMI parameter
definition files."
If the AMI model want to return those values - it should be allowed to - but I 
don't understand why it should be required to.
The EDA tool has the final analyzed waveform and can know the 
PAM4_UpperThreshold and PAM4_LowerThreshold values.

This requirement is an unnecessary burden on the model maker. I am wondering if 
that was our intention..?

Thanks,
Ambrish.