[ibis-macro] Gathering feedback. In the AMI_Init flow, the RX IBIS-AMI model to output the cursor sampling point with regards to a pulse response or step response?

  • From: Hansel Dsilva <hanseldsilva@xxxxxxxxxxxx>
  • To: "ibis-macro@xxxxxxxxxxxxx" <ibis-macro@xxxxxxxxxxxxx>
  • Date: Tue, 31 Mar 2020 19:22:40 +0000

Hi,



Subject, "Gap in IBIS for sampling with statistical mode AMI models", 
presentation at the DesignCon 2020 IBIS Summit.



We are working on a BIRD in enabling when in the AMI_Init flow for an RX 
IBIS-AMI model to tell the EDA tool the cursor sampling point time (seconds).



In IBISv7.0, the AMI_Init flow calls out an impulse response which involves a 
stimulus of 1/time step and does not have any information on the unit interval 
(UI).



The question to ourselves is whether it would it be preferable to make the RX 
IBIS-AMI model when in the AMI_Init flow to output the cursor sampling point 
with regards to a pulse response or step response?

Below is a overview on impulse, pulse and step response in enabling a 
discussion. Feel free to correct me if I happen to be going in the wrong 
direction.



[cid:image003.jpg@01D607BF.D7D11480]



Thanks,

Hansel Dsilva

JPEG image