[AR] Re: Ignition Sequence for Main Valve Timing

  • From: Ben Brockert <wikkit@xxxxxxxxx>
  • To: "arocket@xxxxxxxxxxxxx" <arocket@xxxxxxxxxxxxx>
  • Date: Tue, 2 Aug 2016 20:26:48 +0200

On Tue, Aug 2, 2016 at 6:11 PM, Robert Watzlavick <rocket@xxxxxxxxxxxxxx> wrote:

I wouldn't necessarily say an ASI or torch igniter implies a restartable 
engine. I think of it as more insurance against a hard start since you can 
verify igniter chamber pressure prior to opening the main valves.

You can put an interlock in a pyro igniter. On an end-burning igniter,
embed a thin wire near, but not at, the start of the igniter grain.
When it is disrupted you have a reasonable expectation that the
igniter is burning in a compter-sensable way.

That said I'm all for spark torch igniters, but if I was trying to get
a liquid engine project working as simply and quickly as possible it
probably wouldn't be included. Solenoid valves to run the igniter can
easily cost as much as main ball valves.

Ben

Other related posts: