What to do about the "extra" section that appears at the bottom of the ti1
file?
Suppose I use this command: > targen -d3 -f100 Out100
I get a section with 100 patches (at the top of the file).
Then I get two "extra" sections (at the end of the file).
One with 8 sets and one with 9 sets (see below).
My question: where do these get used?
When I generate the target with printtarg, I only see 100 patches.
/ Roger
----------------------------------------------------------------------------
---------------
CTI1
DESCRIPTOR "Argyll Calibration Target chart information 1"
ORIGINATOR "Argyll targen"
DENSITY_EXTREME_VALUES "8"
CREATED "December 17, 2019"
NUMBER_OF_FIELDS 7
BEGIN_DATA_FORMAT
INDEX RGB_R RGB_G RGB_B XYZ_X XYZ_Y XYZ_Z
END_DATA_FORMAT
NUMBER_OF_SETS 8
BEGIN_DATA
0 100.0000 100.0000 100.0000 95.10649 100.0000 108.8440
1 0.00000 47.36069 100.0000 25.61297 21.62916 97.37627
2 100.0000 0.00000 79.35138 52.42580 26.28975 58.72152
3 0.00000 0.00000 58.99714 6.485834 3.193987 29.89445
4 100.0000 66.65930 0.00000 56.05879 50.50543 7.656144
5 0.00000 35.60114 0.00000 4.685619 8.370208 2.228550
6 84.44436 0.00000 0.00000 28.84279 15.35583 2.304665
7 0.00000 0.00000 0.00000 1.000000 1.000000 1.000000
END_DATA
CTI1
DESCRIPTOR "Argyll Calibration Target chart information 1"
ORIGINATOR "Argyll targen"
DEVICE_COMBINATION_VALUES "9"
CREATED "December 17, 2019"
NUMBER_OF_FIELDS 7
BEGIN_DATA_FORMAT
INDEX RGB_R RGB_G RGB_B XYZ_X XYZ_Y XYZ_Z
END_DATA_FORMAT
NUMBER_OF_SETS 9
BEGIN_DATA
0 100.0000 100.0000 100.0000 95.10649 100.0000 108.8440
1 0.00000 100.0000 100.0000 54.27632 78.94783 106.9308
2 100.0000 0.00000 100.0000 59.70128 29.19948 97.04219
3 0.00000 0.00000 100.0000 18.87111 8.147314 95.12896
4 100.0000 100.0000 0.00000 77.23538 92.85269 14.71507
5 0.00000 100.0000 0.00000 36.40521 71.80052 12.80184
6 100.0000 0.00000 0.00000 41.83017 22.05217 2.913230
7 0.00000 0.00000 0.00000 1.000000 1.000000 1.000000
8 50.00000 50.00000 50.00000 21.14266 22.19007 24.08306
END_DATA