[THIN] Re: The RPC server cannot be contacted on server SERVERNAME

  • From: Jeremy Saunders <jeremy.saunders@xxxxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Thu, 11 Jan 2007 23:45:51 +0900

This is usually not an error, but a common mistake.

When you configure and run discovery in the Access Suite Console, DO NOT
enter a standalone Web Interface server as the name of a "Web Interface
Configuration Server". If you do, you will receive the following error:

The RPC server cannot be contacted on server WIServerName.

Only Presentation Server 4.0 can act as a Web Interface Configuration
Server.

Cheers.

 Kind regards,

 Jeremy Saunders
 Senior Technical Specialist

 Infrastructure Technology Services
 (ITS) & Cerulean
 Global Technology Services (GTS)
 IBM Australia
 Level 1, 1060 Hay Street
 West Perth  WA  6005

 Postal: PO Box 525, West Perth WA
 6872

 Visit us at
 http://www.ibm.com/services/au/its

 P:  +61 8 9261 8412                F:  +61 8 9261 8486
 P:  (Reception) +61 8 9261 8420    E-mail:
 M:  TBA                            jeremy.saunders@xxxxxxxxxxx










                                                                       
             Toby                                                      
             <toby.percival@gm                                         
             ail.com>                                                   To
             Sent by:                  thin@xxxxxxxxxxxxx              
             thin-bounce@freel                                          cc
             ists.org                                                  
                                                                   Subject
                                       [THIN] The RPC server cannot be 
             11/01/2007 10:03          contacted on server SERVERNAME  
             PM                                                        
                                                                       
                                                                       
             Please respond to                                         
             thin@xxxxxxxxxxxx                                         
                     g                                                 
                                                                       
                                                                       




Has anyone experienced this issue when trying to perform a 'Run discovery'
in the Access Suite Console.

System PS4.0 WI4.0

I have been through the Citrix document below and can confirm that the two
accounts are members of the 'Power Users' group and have rights to 'log on
as a service' and 'log on as a batch job'.


http://support.citrix.com/article/CTX108107

Any help appreciated.