[THIN] Re: PNAgent Issue with Mobile Devices - PLEASE HELP!!!!

  • From: "Jon Luchette" <jon.e.luchette@xxxxxxxxx>
  • To: thin@xxxxxxxxxxxxx
  • Date: Tue, 6 Nov 2007 12:03:57 -0500

I actually just upgrade to WI 4.6 and it fixed the problem.  Thank you though...

On Nov 6, 2007 11:20 AM, Pascal Bijnaar <pascal.bijnaar@xxxxxxxxxx> wrote:
> The file gets created from the website Default.ica file. Since you are
> using PNAgent check for this file under
> Inetpub\wwwroot\Citrix\PNAgent\conf.
> Edit this file to remove the duplicate section
>
> -PB
>
> -----Original Message-----
> From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On
> Behalf Of Jon Luchette
> Sent: Tuesday, November 06, 2007 11:07 AM
> To: thin@xxxxxxxxxxxxx
>
> Subject: [THIN] Re: PNAgent Issue with Mobile Devices - PLEASE HELP!!!!
>
> I checked that out and saw the part about duplicate WFClient sections.
> However, my error says the ICA file contains duplicate sections named
> (Encoding). And when I look at the temporary ICA File that gets saved
> to the pda when I attempt to connect, I can see duplicate (Encoding)
> sections that look like this:
>
> [Encoding]
> InputEncoding=UTF-8
> [Encoding]
> InputEncoding=ISO8859_1
>
> If I remove the second (Encoding) line above I can connect, but after
> I close out, that file goes away, and on next connection the 2
> (Encoding) sections are back. Where is that coming from? And why
> doesn't it happen on my laptop or any normal pc that is not a PDA?
>
> On Nov 6, 2007 10:49 AM, Pascal Bijnaar <pascal.bijnaar@xxxxxxxxxx>
> wrote:
> > See CTX113556
> >
> > -PB
> >
> > -----Original Message-----
> > From: thin-bounce@xxxxxxxxxxxxx [mailto:thin-bounce@xxxxxxxxxxxxx] On
> > Behalf Of Jon Luchette
> > Sent: Tuesday, November 06, 2007 9:13 AM
> > To: thin@xxxxxxxxxxxxx
> > Subject: [THIN] PNAgent Issue with Mobile Devices - PLEASE HELP!!!!
> >
> > Hello -
> >
> > I have the PNAgent site setup and working fine for normal desktop and
> > laptop computers.  But when I set up a connection from any one of our
> > PDAs running Windows Mobile, the apps show up on the device properly
> > but I cannot launch the applications.  I get the following error every
> > time:
> >
> > Error Number 2313
> > The ICA Client received a corrupt ICA File.  The ICA file contains
> > duplicate sections named (Encoding).
> >
> > I am testing with the same apps that are working fine with PNAgent
> > from desktops and laptops and all apps are on same Citrix PS 4.0 box.
> > I have tested with 3 PDAs and all get the same exact error message.
> >
> > PLEASE HELP!!!   I really need to get these PDAs working asap.
> >
> > Thanks,
> >
> > Jon
> > ************************************************
> > For Archives, RSS, to Unsubscribe, Subscribe or
> > set Digest or Vacation mode use the below link:
> > //www.freelists.org/list/thin
> > ************************************************
> > ************************************************
> > For Archives, RSS, to Unsubscribe, Subscribe or
> > set Digest or Vacation mode use the below link:
> > //www.freelists.org/list/thin
> > ************************************************
> >
> ************************************************
> For Archives, RSS, to Unsubscribe, Subscribe or
> set Digest or Vacation mode use the below link:
> //www.freelists.org/list/thin
> ************************************************
> ************************************************
> For Archives, RSS, to Unsubscribe, Subscribe or
> set Digest or Vacation mode use the below link:
> //www.freelists.org/list/thin
> ************************************************
>
************************************************
For Archives, RSS, to Unsubscribe, Subscribe or 
set Digest or Vacation mode use the below link:
//www.freelists.org/list/thin
************************************************

Other related posts: