I believe R409 is in the horizontal drive circuit and is a 100 ohm, 2 watt. Bob Waterman, CET® #RI-28 Master Technician License #9109 Service Manager / Parts Manager Gemini Computer, TV, & Security Alarms (508)695-7302 (508)695-7769 FAX geminitv@xxxxxxxxxxx ----- Original Message ----- From: "Phil Bader" <tjanphyl@xxxxxxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Monday, November 08, 2004 11:10 AM Subject: [TechAssist] bad again!,Sanyo DS25330 unusual symptom/fix for dead set,R409 ID? > Thought I fixed this problem with the STR30130 IC.(see original thread > below) > Ran all day. Turned it off, then tried to turn it on. No go. Same issue > as before. Dead. I am replacing C007 (4.7@160V) and R005 (220K) both ib > the PS near the str30130. Maybe they go bad under load, or warm. > I also have a 2 watter R409 I pulled and need to check:. Reads about 7K > but I need it's value. > Thanks. > Phil Bader > > Phil Bader wrote: > > >Originally set was said to be dead after storm. Tho it powered up OK on > >the bench, there were many,many bad solder connections and overheated > >areas of the board. Thoroughly resoldered, tested, and sent home. > >Customer said it never did run at home after repair. Customer returned > >it. Plugge it in. Ran good immediately. Powered on with my remote > >(customer has none) and with the front power button OK. > >I plugged it into the power strip on the test area and dead. Plugged it > >into my Sencore PoweriteII PR570 isolation transformer , and also dead. > >Even tried increasing/decreasing the line voltage.No help. > >Plugged it back in on the bench, works! > >Here's the thing: > >My bench uses a single outlet 1:1 isolation transformer that I always > >plug in the TV under test. The set WORKS with that isolated outlet. > >Plugging in direct into the UN-isolated power strip next to it DOES NOT > >let it power up. My Sencore PR570 DOES NOT let it power up.It's > >isolated! Only my small 1:1 isolation transformer at the bench lets it work. > >I replaced the STR30130 regulator, and problem cleared. Fixed! Note: The > >old str30130 outputted exactly +130 volts DC with perfect picture. > >Now I would understand it working with the isolation and not the direct > >wall outlet,(leakage) but wouldn't even power on with my Sencore > >isolation unit. Strange. > >Phil Bader > > > > > > > > -- > > Philip Bader > Jan Phyl TV Inc. (estab. 1976) > 3420 Recker Hwy. Winter Haven, Fl. 33880 > Fax (863) 299-8821 > email: tjanphyl@xxxxxxxxxxxxxxx > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/