I had one several months ago that did that, it was a shorted blue CRT, disconnect the HV lead to the splitter block and see if it still blows the output.If not remove all hv leads and put in one at a time to isolate which tube. Tony Saracco TCS ELECTRONICS 406 Andra Ct. Gilberts, IL 60136 tcselectronics@xxxxxxxxx ----- Original Message ----- From: "Dan Garris" <dgarris@xxxxxxxxxxx> To: <techassist@xxxxxxxxxxxxx> Sent: Thursday, May 13, 2004 3:31 PM Subject: [TechAssist] Sony KPR46EXR15 Big-Screen > Hi All, > > We have a Sony KPR46EXR15 46" Big-Screen TV which came in "DEAD", no relay > click, no current draw, no blow fuses. Found shorted Q811 2SD1887 HOT, > replaced it but keeps shorting out the HOT. I do not have the schematic. Has > anyone seen this problem before? Chassis=SCC-F-19D-A or SCC-F-19E-A. > > Dan Garris > Garris TV > New Bern, NC 28560 > DGarris@xxxxxxxxxxx > > > > -------------------------------------------------------------------------- --- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/