Need someone that is familiar with this set to help. It will not start unless I go through a routine of unplugging any one of the three combination convergence /vert yolk plugs. Then plugging the a/c cord in and then plugging the yolk back in. Now the set will start up. If I shut the set off, it will start up again if I don't wait too long. If I unplug the a/c, then I have to remove any of the yolk plugs and repeat the routine. The standby voltage does not come up unless I do the routine. One other consideration, the print calls for +&- 25 volts for the convergence amps. This supply is putting out +&-40v in standby and +&-33V in run. This doesn't seem normal, but find nothing. Other standby supplies are normal. I have been going around in circles on this thing too long. I have replaced the amps on the convergence amp board and a 5v regulator. Every ave. I go down ends up a dead end. Have heated and used all my freeze. Have more coming. Tried to get help from factory,wont ta lk to me. Not Sharp ASC. Sorry to write a book but really could use some help. Paul Paul ,B Central TV&Video 911W Grand Ave Grover Beach Ca. (805)481-8084 ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/