[TechAssist] Re: Philips 27pt6441/37 Blows fuse

  • From: "repair11" <repair11@xxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Wed, 1 Feb 2006 10:35:16 -0600

Barry, replace 3509 (degaussing PTC) pn#21226630019,hth.





Charles Betzler
Best Electronics
repair11@xxxxxxx
----- Original Message ----- 
From: "Barry" <foxhole@xxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Wednesday, February 01, 2006 10:18 AM
Subject: [TechAssist] Philips 27pt6441/37 Blows fuse


I have had two of these L04.1UAA chassis in this month with the 4amp SB fue
blown. The deguase circuit draws in excess of 5 amps AC momentarily at start
up. I have replaced the fuse and they play fine. Has anyone seen this
failure?
Thank You,
Barry MacInnes
Television Service Clinic
2 Church St. W.
W. Lebanon,NH 03784
foxhole@xxxxxxxxx

----------------------------------------------------------------------------
-