Open up the plastic covering on transformer and find old fuse link, install a new trermo fuse placing it in contact with the windings and close back up. Use a 103 deg C ei NTE8103 Al G AURTRON wrote: > Need standby power transformer for Mit. Model CK2630R.SAMS # 2771-1. Part # > 350P439020 Transformer is mounted in cabinet separate from chassis both > primary and secondary plug into mother board. Input = 120VAC Secondary 18VAC > Source for +20 VDC standby voltage. Internal fuse is open and for safety > liability would like to replace. Part NLA Tritronics. Either new or used > would suffice. Please reply to email listed below with price if you have > available. > TIA > > Don > Aurora Electronics > Florida > Aurtron@xxxxxxxxxx > > ----------------------------------------------------------------------------- > Lost Password: > http://www.tech-assist.org and select "Login Problems?". > Email Archives: > //www.freelists.org/archives/techassist/ > ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/