[TechAssist] Re: KV27S25

  • From: "Dave Routson" <davestv@xxxxxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Sat, 6 Oct 2001 16:59:06 -0500

Hi Rudolph,
   No notes on this one yet but ps looks
like simular to older set with some
variations. Would suspect VDR 601 and possibly R622 if VDR 601 bad. It
has different part number but in same
category # is 1-810-974-11 and R622
is 10ohm fusible.
hope this helps some.
   Dave Routson
----- Original Message -----
From: "Rudolph" <rudolph@xxxxxxxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Saturday, October 06, 2001 12:58 PM
Subject: [TechAssist] KV27S25


> Hi folks
>
> The regulators that are going bad are Q601 & Q601. Also found R607. These
are all on the power supply board.
>
> Rudolph
>
> Help make your TechAssist online repair tips
> database better!  Submit your fixes here:
> http://www.circuitwork.com/techassist/tip/#tips
> To unsubscribe write to:
> techassist-request@xxxxxxxxxxxxx
> with  unsubscribe  in the subject line.

Help make your TechAssist online repair tips 
database better!  Submit your fixes here: 
http://www.circuitwork.com/techassist/tip/#tips
To unsubscribe write to:
techassist-request@xxxxxxxxxxxxx 
with  unsubscribe  in the subject line.

Other related posts: