Shaun, Do you get any raster? Full horizontal and vertical deflection? Did you try disconnecting the HOT (collector) to isolate the FBT to see if excessive load goes away? You could have a bad FBT breaking down under load or a shorted circuit of secondary of the FBT. Just my thoughts, hope this helps some. David Lessard Mr_fixit@xxxxxxxxxxxx Alexandria Electronics Alexandria, Ontario -----Original Message----- From: techassist-bounce@xxxxxxxxxxxxx [mailto:techassist-bounce@xxxxxxxxxxxxx] On Behalf Of Shaun Sent: Wednesday, June 23, 2004 12:52 AM To: tech Subject: [TechAssist] GE 27GT619 (CTC185AB) Power problem This set had the horz. output shorted the regulator shorted and 2.7 ohm 15 watt power resistor open. I replaced them all and the 231523 kit. Now the set turns on but it is drawing about 3.5 AMPS and is probably going to blow parts if I leave it on too long. What else am I missing. I read through all the tips but nothing really stands out other than the I.H.V.T but it rings good. Shaun Advanced Electronics 224 West Riverview Ave. Fort Morgan, CO 80701 ------------------------------------------------------------------------ ----- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/ ----------------------------------------------------------------------------- Lost Password: http://www.tech-assist.org and select "Login Problems?". Email Archives: //www.freelists.org/archives/techassist/