Customer said that set went dead as the set was on. No tape was in the
VCR. When first powered up, relay clicks on and off, HV for a split
second. Set then goes into shutdown. B+ is 119.4 volts before power
button is pressed, after power button is pressed, B+ drops to 2 volts as
set goes into shutdown. Could not find any shorts or open resistors.
All caps checked good for ESR. TIA