-------- Original Message -------- Subject: Sylvania console SRP753 (25S102 chassis)HOT,pico fuse blows Date: Thu, 18 Oct 2001 16:33:15 -0400 From: Phil Bader <philbad@xxxxxxxxxx> Organization: Jan Phyl TV Inc. Winter Haven, Fl. Estab. 1976 To: "CONSUMERELREPAIR-L@xxxxxxxxxxxxxxxxxxxx" <CONSUMERELREPAIR-L@xxxxxxxxxxxxxxxxxxxx> Found HOT Q502 shorted and 2.5a pico B+ fuse open . Replaced HOT and fuse,plugged in and checked standby volts. I only had +15V at coll of HOT, but the +9V and +5V stby was good.Did not find any shorted small transistors or diodes.Turned on,heard a rush of HV and SSSSSHHHOOP.dead. HOT and pico fuse bad again. Pulled the scan cap C505 (10nF@1600V) measured OK. Any history on this? Phil Help make your TechAssist online repair tips database better! Submit your fixes here: http://www.circuitwork.com/techassist/tip/#tips To unsubscribe write to: techassist-request@xxxxxxxxxxxxx with unsubscribe in the subject line.