[TechAssist] Re: CTC 177 Pulls in from sides after start up

  • From: "Webster TV" <webstertv@xxxxxxxx>
  • To: <techassist@xxxxxxxxxxxxx>
  • Date: Thu, 19 Aug 2004 09:46:08 -0500

Tom,

Diode CR4403(#243636) or Cap C4407(#214754) in H.O.T. collector circuit can
cause narrow bowed in sides of raster.

                               Dan Webster
                               Webster's TV
                               Shullsburg, Wi.
----- Original Message -----
From: "Thomas Woodward" <thomas.woodward@xxxxxxxxxxx>
To: <techassist@xxxxxxxxxxxxx>
Sent: Tuesday, August 17, 2004 10:37 AM
Subject: [TechAssist] CTC 177 Pulls in from sides after start up


> Hello
> I have a CTC 177 that is pulling in on the  sides a few seconds after
> start up
> I have replaced the stk-730  which was shorted
> Now I have the horizontal problem
> Any suggestions
>
> Thanks
> Tom
>
> --
> Thomas S. Woodward
> Multimedia Networks Manager
> Master tech 09165
>
> Simmons College
> 300 The Fenway
> Boston Ma. 02115
> 617-521-2764
> 617-893-9226 (Cell)
> mailto:woodwart@xxxxxxxxxxx
>
>
>
> --------------------------------------------------------------------------
---
> Lost Password:
> http://www.tech-assist.org  and select "Login Problems?".
> Email Archives:
> //www.freelists.org/archives/techassist/
>


-----------------------------------------------------------------------------
Lost Password:
http://www.tech-assist.org  and select "Login Problems?".
Email Archives:
//www.freelists.org/archives/techassist/