otamain failed during R12 upgrade

Hit the error described by note 1306168.1. Per the note, disabled the 
constraint and restarted the worker. The worker finished. However, now I can 
not re-enable the constraint. How do I re-enable the constraint.
JBECKSTROM@or01>alter table ota.ota_event_associations enable constraint 
ota_event_associations_uk2;
alter table ota.ota_event_associations enable constraint 
ota_event_associations_uk2
*
ERROR at line 1:
ORA-00955: name is already used by an existing object

Jeffrey Beckstrom
Database Administrator
Greater Cleveland Regional Transit Authority
Information Systems
1240 W. 6th Street
Cleveland, Ohio 44113


--
http://www.freelists.org/webpage/oracle-l


Other related posts:

  • » otamain failed during R12 upgrade - Jeffrey Beckstrom