page 4: Environment variables- Is the environment variable name fixed At present there seems to be only one variable defined "AMISearchPath" page 11: Init_Returns_Filter Question on 'WMK' comment what is the combination of impulse response and filter? Is it same as modified impulse response? How does this combination circumvent the problem of deconvolving/deriving filter response? page 14 Rx_Receiver_Sensitivity: How the EDA/model is expected to use this information in a 'standard' way during simulation/post processing? page 18 tap input examples (mySampleAMI (txtaps .05 -.1 .7 .1 -.05) (strength 6)) tap output through parameter_out (mySampleAMI (txtaps .06 -.05 .8 .05 -.04) (framis "Overloaded")) there are two additional parameters here 'strength' and 'framis' does that mean parameter_in and parameter_out need not be consistent? --------------------------------------------------------------------- IBIS Macro website : http://www.eda.org/pub/ibis/macromodel_wip/ IBIS Macro reflector: //www.freelists.org/list/ibis-macro To unsubscribe send an email: To: ibis-macro-request@xxxxxxxxxxxxx Subject: unsubscribe