[ibis-editorial] Re: Pin Mapping BIRD

  • From: "Bob Ross" <bob@xxxxxxxxxxxxxxxxx>
  • To: "'IBIS-Editorial'" <ibis-editorial@xxxxxxxxxxxxx>
  • Date: Sun, 21 Aug 2016 23:56:21 -0700

All,

 

This BIRD looks ok to me, but I am not sure we need to change the column
length

limits from 15 to 40 characters for the [Pin Mapping] *_ref columns.  I
understand

the reason.  However, the [Pin Mapping] *_ref columns are for POWER or GND 

pin signal_names.  I am not aware of any commercial device that uses more
than

15 characters in its POWER or GND signal name.

 

Because we also have a line limit of 120 characters, the increase to 40
characters

for each *_ref columns would theoretically exceed our line length limit..

 

So, unless someone can point to a practical need to increase the limit,  I

would keep the 15 character limit to minimize parser work and to avoid the

the line length issue.  (We could do the opposite, and automatically

impose a 15 character limit for any signal_name used as a bus_label)

 

(Note, some devices have more the 15 characters for the I/O signal

names, where the pin might be used in some dual mode and have two

joined names.)

 

Bob

 

From: ibis-editorial-bounce@xxxxxxxxxxxxx
[mailto:ibis-editorial-bounce@xxxxxxxxxxxxx] On Behalf Of Walter Katz
Sent: Friday, August 19, 2016 9:23 AM
To: 'IBIS-Editorial'
Subject: [ibis-editorial] Pin Mapping BIRD

 

All,

 

This BIRD contains my recommended changes to the IBIS [Pin Mapping] section.

 

Walter

 

Walter Katz

 <mailto:wkatz@xxxxxxxxxx> wkatz@xxxxxxxxxx

Phone 303.449-2308

Mobile 303.335-6156

Other related posts: