Gerhard Fuernkranz wrote:
Graeme, I notice that xicclu -pl -g -ir -fif x22-ag.icc gives different result in 1.0.3 and 1.1.0 (see attachments). The old one (1.0.3) actually looks more reasonable for a matrix/gamma profile.
Hi Gerhard, it depends on what you were expecting :-) I modified xicclu -g to better match the -kp controls so that target points can be directly transcribed from one to the other. To do this -g now plots from the white point to the black point. Since the profile in question has a non-zero black point, the results are different. Whether the non-zero black point is correct is another question.. cheers, Graeme Gill.