[argyllcms] Re: ccmx for Spyder 3

  • From: Graeme Gill <graeme@xxxxxxxxxxxxx>
  • To: argyllcms@xxxxxxxxxxxxx
  • Date: Fri, 10 Jun 2011 17:45:49 +1000

umberto.guidali@xxxxxxxxxx wrote:
Do you think that is possible to "convert" this file into a ccmx
standard file??? Should be nice to continue to use Argyll to calibrate
&  profile my new monitor......

Yes, it looks like the raw data from the reference and the instrument.
It should be possible to convert it to two .ti3 files, and feed it
into ccmxmake.

Graeme Gill.